Kilsen is the world's leading manufacturer of fire detection equipment. Fire panel, detection equipment, warning siren and flashers, call buttons etc. manufactures safety equipment.
UTC Carrier Kilsen Fire Detection Equipment
Kilsen fire detection and alarm systems, one of the leading brands of UTC Carrier Fire & Security, are offered with a widespread network throughout Turkey with Platin Technology service quality.
UTC Carrier Kilsen Addressable systems have loop lines to which sensing elements are connected. The number of loop lines and the wiring distance depends on the panel used. 125 detectors + 125 inputs, outputs or buttons can be connected to a loop line. A total of 250 addressed elements can be connected. Sensing elements in the loop can be divided into zones and each sensing element can be individually perceived by the panel thanks to the addressing software it contains. In other words, when any detector detects, the location of the detector can be determined individually on the panel or on the pc where the projects of the building, which can be used optionally, are loaded. Conventional systems and addressable systems are selected and sized according to their application locations. Conventional elements are sufficient for systems with a small number of sensing elements and offer cheap solutions.
Advantages of UTC Carrier Kilsen Addressable Fire Detection Systems
1- In addressable systems, clear information of the location of the detector where the information such as alarm, malfunction etc. comes from can be reached. In conventional systems, region (floor) information comes. The net location of the detector must be checked for the region.
2- In addressable systems, alarm, error, loss, malfunction and calibration information of the detectors are displayed on the panel as a point.
3- In addressable systems, 125 + 125 equipment can be operated on each cable line. This number is limited to 20 detectors in conventional systems.
4- In addressable systems, the system continues to work in the problem of the wiring line, providing information about where the problem is. In conventional systems, the part after the line is completely disabled.
5- Equipments such as input module, output module, siren module etc. from addressed systems can operate over the loop line. In conventional systems, general alarm and error information can be received from the panel.
6- In addressable systems, wide range of alarm scenarios that will be activated in case of fire can be applied.
In summary, it offers solutions in large and medium-scale projects with low infrastructure, operating and initial investment costs thanks to its modular structure and technology.
UTC Fire & Security Product Kilsen KFP-C fire alarm panels offer simple solutions for small and medium-sized conventional applications, thanks to their advanced intelligent processing speed. It is designed to be modern in a structure that can adapt to many different architectural decorations. It exhibits a different appearance with its curved front cover. User controls are on the striking gray color leksan on the panel. This conventional detection system, with its easily programmable optional cards and modules, provides numerous advantages to both investors and system builders. Standard Features • Modern and elegant design • Easily removable parts for fast and orderly installation • Regional setup modes • Supervised alarm notification and fire brigade connection * outputs • Class change, day / night, remote reset, extended fire routing delay * delay delay functions • Auxiliary 24VDC output for resetting • Ready-made special function support: - EN54 compliant user authorization levels - mixed zone - Ability to detect all errors from the front panel - single person walk test • Auxiliary standard and supervised relay output cards • Scandinavian Switch and Alarm Counter * supported panel types • Networking up to 64 zones * Not available in 2-zone models Kilsen Fire Alarm System Features • Detector, button or mixed zone (button and detector) • KL700 series detector support • Programmable inputs for functions such as remote reset, class change (school bell), day / night mode delay control • Supervised relays on the panel for fire routing and alarm warning • 110 VAC or 240 VAC supply voltage, 50/60 Hz support • Ability to select standard or resettable type auxiliary supply output • Ability to control the output relays on the panel auxiliary cards by controlling alarm information with AND and OR functions
UTC fire & security product Kilsen Conventional Fire Alarm Control Panels
KFP-CF2-19 Conventional Fire Alarm Control Panel - 2 Zones (Turkish)
KFP-CF4-19 Conventional Fire Alarm Control Panel - 4 Zones (Turkish)
KFP-CF8-19 Conventional Fire Alarm Control Panel - 8 Zones (Turkish)
Relay Card with 2010-1-RB4
2010-1-NB
2010-1-SB4 Supervised Relay Card
KFP-CF8-LK-19 Turkish Panel Kit (Spare)
KFP-CF8-LK-25 Russian Panel Kit
KFP-CF8-LK-99 English Panel Kit
UTC fire & security product Kilsen conventional Detectors
KL731Conventional Optical Smoke Detector
KL731BConventional Optical Smoke Detector - Black
KL710Conventional Heat Detector
KZ700 Conventional Detector Base
KZ700B Conventional Detector Base - Black
KZ705R Conventional Relay Detector Base - 12V
Conventional Fire Alarm Button
DMN700R Conventional call point, with LED, including glass,
red, flush type
Surface mounting box
UTC fire & security product Kilsen Intelligent Addressable Fire Alarm Control Panels
KFP-AF1-19 Intelligent Addressable Fire Alarm Control Panel
1 Loop (Turkish)
KFP-AF1-S-19 Intelligent Addressable Fire Alarm Control Panel
Small - 1 Loop (Turkish)
KFP-AF2-19 Intelligent Addressable Fire Alarm Control Panel
Small - 2 Loops (Turkish)
KFP-AF2-S-19 Intelligent Addressable Fire Alarm Control Panel
2 Loops (Turkish)
KFP-AFR-S-19 Intelligent Addressable Fire Alarm Repetition Panel (Turkish)
2010-2-NBRS485 Network Card
KFP-A-LB2 loop Expansion Board
(KFP-AF2-19 is used to make 4 loops))
KFP-AF2-PRT-19
KFP-AFR-19
KFP-A-LK-19 Turkish Panel Kit (Spare)
KFP-A-LK-25 Russian Panel Kit
KFP-A-LK-99 English Panel Kit
KFP-A-LK-15 Arabic Panel Kit
2010-2-DACTDigital alarm transmitter
2010-2-PIB Environmental Interface Card
2010-2-PIB-8I Environmental Interface Board 8 input
2010-2-PIB-8I8O Environmental Interface Board 8 input / 8 output
2010-2-PIB-8O Environmental Interface Card 8 output
Kilsen Printer Connection Modules from UTC fire & security
2010-2-PRT Built-in printer
2010-2-232-KITRS-232 Printer connection module
UTC fire & security product Kilsen Addressable Detectors
KL731AO Optical Smoke Detector
KL731ABOptical Smoke Detector - BLACK
KL735AK Combined Optical Smoke / Heat Detector
KL710A Heat Detector
KZ705Detector Base
KZ715 Base with insulator
KZ715A Siren Detector Base
PA25 / 3LLED Indicator
PG700NDedector Handheld Programming Device
Optical unit for KOB700KL731-KL731A detectors (packs of 10)
Duct Type Detector Enclosures (Detector and Base must be ordered separately)
FDD710 Duct type conventional smoke detector housing
(excluding detector and base)
FDD710LP1.5m sampling / expansion tube
Mounting bracket for FDD710MBFDD710, for uneven ducts
UTC fire & security product Kilsen Addressable Fire Alarm Button
KAL455 Addressable Manual Call Point, Red,
Surface Mount, Glass included
KAL455E Outdoor Addressable Manual Call Point, Red,
Surface Mount, Including Glass, IP67
Addressable Fire Button (Mcp), Red,
With LED, Surface Mount (Compatible with Kılsen Addressable System)
UTC fire & security product Kilsen Input / Output Modules
KAL710 Addressable Zone Monitoring Module
1 Zone (including mounting base)
KAL714C Addressable Zone Monitoring Module
4 Zones (including mounting base)
KAL730 Addressable Output Module
1 Outlet (including mounting base)
KAL734CAddressable Relay Output Module
4 Outlets (including mounting base)
KAL740 Addressable Supervised Relay Output Module
(including mounting base)
KAL760 Addressable Input Module - 1 Input (including mounting base)
E760 Address Entry Module, 1 Input (Including Housing)
KAL775 Addressable Loop Isolator Module (including mounting base)
KAL790
UTC fire & security product Kilsen Siren and Warning Devices
AS363Siren, 32 tone, red, IP21, with base (shallow base)
AS364Siren, 32 tone, red, IP21, with base (deep base)
AS366 Siren and strobe, 32 different tones, red lens, IP21
with base (shallow base)
AS371 Outdoor Siren and Beacon, multi-tone, red,
IP55, with mounting base, 110 dB
FA340Xenon flasher, Red lens, White base, IP21
FA355LED Flasher, Red Lens, Red Deep Base, IP65
SK08A Addressable Sounder, Loop Powered
G1RF-HD-EGenesis Temporal Horn, RED, with FIRE, EU
G1R-HDVMGenesis Temporal Horn-strobe, RED
G1RB-MPBackbox, Package of 10, Red
Monitoring - Control software
2010-2GUI-FCGraphical interface - Control and monitoring software
2010-2GUI-MOGraffic interface - Monitoring software
UTC fire & security product Kilsen Network Expansion Licenses
2010-2-PAK-NET128Network Expansion - 32 nodes / 128 loops
2010-2-PAK-NET256Network Expansion - 64 nodes / 256 loops
UTC fire & security product Kilsen Remote Monitoring Licenses
2010-2-PAK-RMOH Remote Monitoring - Contact ID over IP
2010-2-PAK-RMSDK Remote Monitoring - SDK over IP
UTC fire & security Carbon Monoxide (CO) Detection Panel and Detector
KM302 Carbon Monoxide (CO) Detection Control Panel - 2 Zone
KM304 Carbon Monoxide (CO) Detection Control Panel - 4 Zones
KMD300 Carbon Monoxide (CO) Detector
KFP-CX3-993 Zoned Conventional Extinguishing Panel
DMN700W03-KITR White Button, Extinguish Cancel Button, Surface Mount,
Resettable, Protected
Surface Mount Box, White, DM788W
DMN700Y03-KITR Yellow Button, Extinguishing Started Button, Surface Mount,
Resettable, Protected
DMN787Y Surface Mount Box, Yellow
DM700B03-KITR Blue Button, Extinguish Wait Button, Surface Mount,
Resettable, Protected
Surface Mount Box, DM788B, Blue
DM711EN54 approved Button Glass (10 pcs pack)
Flame Detectors
FF742 Microprocessor based Flame Detector, Dual IR, in zinc alloy case (IP65), with relay output, EN54 approved
FF746 Microprocessor based Flame Detector, Dual IR, flame-proof enclosure (IP66), with alarm and fault relay output, EN54 approved, EEx d IIC T6
FF747 Microprocessor based Flame Detector, Intrinsic Safe, Dual IR, in Zinc alloy case (IP65), with relay output, EN54 approved
FF751Microprocessor based Flame Detector, in UV / Dual IR Zinc alloy case (IP65), with relay output, EN54 approved
FF756 Microprocessor base Flame Detector, UV / Dual IR, flame-proof enclosure (IP66), with alarm and fault relay output, EN54 approved, EEx d IIC T6
FF762 Microprocessor based Flame Detector, Triple IR, in Zinc alloy case (IP65), with relay output, EN54 approved
FF766 Microprocessor based Flame Detector, Triple IR, flame-proof enclosure (IP66), with alarm and fault relay output, EN54 approved, EEx d IIC T6
FF767 Microprocessor based Flame Detector, Intrinsic Safe, Triple IR, in Zinc alloy case (IP65), with relay output, EN54 approved
FF703UV / IR Tester
Beam Detectors
FD705RVDS Beam detector 5 - 50m, VDS approved
FD710RVDSBeam detector 50 - 100m, VDS approved
Auto Aligned Motorized Type Beam Detector Accessories
Mounting bracket for FD-MB20FD800 Series Detector Reflectors
FD-MB30 Single reflector adapter for 8-50 m
(Used with FD-MB20)
FD-MB40 Quad reflector adapter for 50-100 m
(Used with FD-MB20)
Cable Type Linear Heat Detection - Analog
DT650LD Linear Heat Detection Cable Conventional Control Module
HC650 Linear Heat Detection Cable - PVC - 500m
HC650-MD Linear Heat Detection Cable - PVC - 1m
HC650S-MD Linear Heat Detection Cable - Stainless Steel - 1m
Cable Type Linear Heat Detection - Digital
HCD6067 Constant temperature sensing cable 67 ° C - 500 m
HCD6067-M Constant temperature temperature sensing cable 67 ° C - 1 m
HCD6087 Constant temperature sensing cable 87 ° C - 500 m
HCD6087-MS constant temperature sensing cable 87 ° C - 1 m