top of page

Site Search Results

254 items found for ""

  • EN 54 4 Sertifikalı Güç kaynakları | Platin Teknoloji

    EN 54 4 Certified Power supplies Platin Teknoloji offers C-TEC and ELMDENE products, which are among the world's largest EN54 EN54-4 Approved power supply manufacturers, to the professionals of the Fire Detection systems sector throughout Turkey. Due to the increasing need to use the power supplies that feed all equipment included in the system in fire detection scenarios and integration applications, which have recently increased in the fire detection system, and the EN54-4 compliance requirements of all equipment included in the fire detection system, UPS function power supply needs with battery charging have occurred. TYPICAL USE Beam / Beam detectors, Early fire detection devices / air sampling devices, Other systems integrated into the fire system, air evacuation systems, External sounder systems or any device that fulfills a mandatory function of the fire alarm system to work uninterruptedly and in accordance with EN 54-4 standards is used for. Status LEDs on the power supply 1 flash = Mains Failure. 2 flashes = Low Battery Voltage. 3 flashes = Battery Voltage Critical. 4 flashes = Charger Failure. 5 flashes = Charger OK (Battery is actively charging or float charging) 6 flashes = No Battery Installed (DIP Indicates Switch 4 position). 7 flashes = Battery Resistance Error (Level set by DIP Switch 2 position). 8 flashes = Output Overvoltage. Battery Failure It must monitor the battery resistance according to EN54-4 / A2. The failure threshold is directly related to the ability of the battery to deliver the rated current to the load. For example, batteries that have not been charged for an extended period of time during shipping and / or distribution will drop causing an increase in internal resistance. If a degraded battery is installed, an error will be displayed by the PSU as specified by EN54-4 / A2. Data Transfer Out Data on the status of the switch mode power supplies that will provide uninterrupted energy to the fire system can be exported from the PSU's bidirectional data port. Available data includes thermistor measurements; battery pole voltage; system voltage at load terminals; battery charge current; load current; battery impedance and ASCII text string status messages. The use of these data can be provided with additional equipment. Power supplies have models suitable for use in all weak current systems where uninterrupted and controlled power is required. ELMDENE EN54-4 Certified Battery powered power supplies with UPS function suitable for use in fire detection systems Product Code Output Current Usable BATTERY STX2401-T 1A 24 VDC 1 A 2 X 12 VDC 1,2 Ah STX2401-C 1A 24 VDC 1 A 2 X 12 VDC 7 Ah STX2402-C 2A 24 VDC 2 A 2 X 12 VDC 7 Ah STX2402-E 2A 24 VDC 2 A 2 X 12 VDC 17 Ah STX2405-C 5A 24 VDC 5 A 2 X 12 VDC 7 Ah STX2405-E 5A 24 VDC 5 A 2 X 12 VDC 17 Ah STX2410-E 10A 24 VDC 10 A 2 X 12 VDC 17 Ah STX2410-H 8A 24 VDC 8 A 2 X 12 VDC 38 Ah STX2410-E + BATT-BOX-65 24 VDC 7.2 A 2 X 12 C-TEC EN54-4 Certified Battery powered power supplies with UPS function suitable for use in fire detection systems BF362-1 EN54-4 Certified Auxiliary Supply and Battery Charger - 24V / 1,5A DC - Space for 2x12V / 17Ah BF362-3 EN54-4 Certified Auxiliary Supply and Battery Charger - 24V / 3A DC - Space for 2x12V / 12Ah BF362-5 EN54-4 Certified Auxiliary Supply and Battery Charger - 24V / 5A DC - Space for 2x12V / 18Ah BF360-12 EN54-4 Certified Auxiliary Supply and Battery Charger - 12V / 2A DC - Space for 1x12V / 7Ah battery EN 54 standardı, yangın algılama ve alarm sistemleri için Avrupa'da kabul edilen bir dizi standarttır. Bu standart, yangın güvenliği uygulamalarını geliştirmek ve yangın anında hızlı müdahale sağlamak amacıyla tasarlanmıştır. EN 54, çeşitli bileşenleri kapsar; bunlar arasında dedektörler, alarm panelleri ve sistem bileşenleri yer alır. Standart, sistemlerin güvenilirliğini ve etkinliğini artırarak, olası yangın durumlarında zamanında uyarı yapılmasını sağlar. Ayrıca, uluslararası bir uyumluluk sunarak farklı ülkelerdeki uygulamaların standartlaştırılmasına yardımcı olur. Bu sayede, binalarda yangın güvenliği önlemleri daha sistematik ve etkili bir şekilde uygulanabilir. EN 54, düzenli test ve bakım gereksinimleri de belirler. Bu, sistemin sürekli olarak işlevsel kalmasını sağlar ve yangın güvenliği açısından kritik öneme sahiptir. Yangın algılama sistemlerinin tasarımı, montajı ve bakımı, standartlar doğrultusunda gerçekleştirildiğinde, can ve mal güvenliğini büyük ölçüde artırır. Sonuç olarak, EN 54 standardı, yangın güvenliği alanında temel bir referans noktasıdır. Yangın algılama ve alarm sistemlerinin etkinliğini artırarak, insan hayatını koruma konusundaki ultimate hedefe ulaşmamıza yardımcı olur. ​ EN 54 Standardının Tarihçesi EN 54, yangın algılama ve alarm sistemleri için Avrupa'da belirlenen standartlar dizisidir. Bu standartların tarihçesi, yangın güvenliği alanındaki gelişmeler ve teknolojik ilerlemelerle şekillenmiştir. 1. Başlangıç Dönemi EN 54 standardı, 1980'lerin sonlarına doğru Avrupa'da yangın güvenliği ile ilgili ortak bir çerçeve oluşturma amacıyla geliştirilmiştir. O dönemde, farklı ülkelerdeki yangın güvenliği uygulamaları arasında büyük farklılıklar vardı. Bu durum, özellikle uluslararası projelerde sorunlara yol açmaktaydı. 2. Standartların Gelişimi 1990 yılında ilk EN 54 standardı yayımlandı. Bu standart, temel yangın algılama sistemleri için gereksinimleri belirleyerek, sektördeki profesyoneller için bir referans noktası oluşturdu. Zamanla, sistem bileşenleri ve fonksiyonları hakkında daha fazla detay sunan çeşitli alt standartlar geliştirildi. 3. Yenilikler ve Revizyonlar EN 54, teknolojinin ilerlemesiyle birlikte sürekli olarak güncellendi. 2000'li yıllarda, kablosuz sistemlerin ve akıllı dedektörlerin kullanımının artmasıyla birlikte, standartta bu yenilikleri kapsayan düzenlemeler yapıldı. Bu güncellemeler, sistemlerin güvenilirliğini ve performansını artırmayı hedefledi. 4. Uluslararası Uyum EN 54, Avrupa'nın ötesine geçerek dünya genelinde yangın güvenliği uygulamalarında referans haline geldi. Bu, farklı ülkelerdeki standartların uyumlu hale getirilmesine yardımcı oldu ve uluslararası inşaat projelerinde yangın güvenliği çözümlerinin entegrasyonunu kolaylaştırdı. 5. Günümüzde EN 54 Günümüzde EN 54, yangın algılama ve alarm sistemleri için uluslararası bir standart olarak kabul edilmektedir. Yangın güvenliği mühendisleri, mimarlar ve diğer profesyoneller için önemli bir kaynak olmanın yanı sıra, binaların güvenliğini artırmaya yönelik yenilikçi çözümlerin geliştirilmesine de katkıda bulunmaktadır. ​ EN54 Standartlarına Uygun Yangın Algılama ve Alarm Çözümleri

  • genesis edwards | Platin Teknoloji

    Genesis Edwards Siren Flasher Equipment Founded in 1872 by Robert Edwards and David Rousseau, the Edwards Company has a rich history of success. 1872- Edwards and Company was founded by Robert Edwards and David Rousseau to discover the new "Electric" phenomenon and to manufacture, sell and install battery-powered gas-fitting igniters. Among the company's first customers is a New York City church where the sextons previously climbed a 100-meter ladder to the light gas armatures above the rows. 1873 Rousseau withdraws from the partnership and is replaced by Adam Lungen. They invented and developed an electric doorbell and a burglar alarm. 1880 - The Edwards Company leaves the basement of the Lungen family's jewelery shop, moves into a three-story facility, and begins to manufacture wooden canals and enclosures for burglar alarms. 1881 - Robert Edwards receives his first patent for an electric bell. Other patents quickly followed: a retractable warning device (1882); an electric gas burner lighter (1883) for push button operation; and an electric door opener (1884). 1884 - Edwards displayed its products at the first electricity fair in the United States. Held in Philadelphia, was called the "Electricity Exhibition, National Electricians Conference". 1886 - Alongside burglar alarms and fixture igniters, the Edwards catalog lists electrically wound clocks, program systems, and coils for the first time. 1896 - Edwards stopped installing electrical devices and limited his activities to the design and manufacture of signaling, communication, and protection equipment. 1900 - Horizontally operated piston bell designed. The basic design is used for today's Edwards AdaptaBel. 1901- First national distributor of "household electrical appliances" appointed by Edwards Company. 1903 - The New York Stock Exchange bell was set to initiate the start and end of each day trading. 1912 - Edwards car call is introduced, reporting all-weather conditions for department stores. 1915 - Bronze Medal of Honor for electrical products awarded to Edwards at the Panama-Pacific Fair, San Francisco, CA. 1917 - Waterproof bells and submarine detection devices made for the Navy, a special telegraph apparatus developed for the Signal Corps. 1927- The Holland Tunnel is opened with Edwards emergency signaling installed on 2-mile twin tubes. Electrical devices ordered from Edwards for the White House. 1929 - Montreal Curb Exchange orders "Silent Call" alerts. Edwards & Company of Canada is formed. 1935 - Lungen buzz vibrating probe at the bottom of the world's deepest oil well 11,300 feet below the earth's surface. Edwards guard tour, sprinkler and fire alarm system installed at Rockefeller Center in New York City. 1936 - New glass-breaking fire stations are introduced to replace the hammer and chain types. 1938- Boeing Aircraft Co. Edwards signaling devices and signaling systems for double-deck flying clipper ships. 1941 - The world's largest car ferry, Midland City leaves Michigan waterways equipped with Edwards waterproof signals. Budd Co. has equipped its latest "Silver Meteor" trains with Edwards reporters. 1945- Edwards, Fifth Army-Navy E. 1948 - Edwards-made fire alarms are installed on SS President Cleveland and SS President Wilson, new cruise ships traveling around the world. The James H. McGraw Award, Manufacturer Medal of the Year, was presented to RS Edwards. 1950- New Edwards factory opens in Owen Sound, Ontario, Canada. 1951- Teardrop fire alarm station introduced: Called "a model of impeccable simplicity" by the Associated Press. 1956 - Production facilities for distributor products transferred to the new Pittsfield, Maine plant. 1961 - An audiovisual nurse call with patient privacy feature shown at the American Hospital Association Exposition, Atlantic City, NJ. 1962 - Edwards Corporation becomes a business unit of General Signal Corporation. 1964- Edwards fire alarm system was determined for 52-storey Vertical Assembly Building in Cape Kennedy, the largest structure in the world. 1965- Edwards systems installed in the Visual Arts Museum designed by LeCorbusier for the Harvard University campus. 1966 - Manitoba, the largest municipal public system in Canada designed and established by Edwards, police and fire control centers for the city of Winnipeg. 1967 - Edwards supplies 77 fire alarm systems to Expo '67, Montreal. 1971- JFK Performing Arts Center was equipped with Edwards fire alarm system. 1973 - Edwards buys Electrons, Inc., maker of Cat. 280 series heat detector. 1976 - Edwards introduces a new ionization smoke detector. 1979- Edwards introduces new Greenline Series Fire Alarm Chimes. 1981- Edwards incorporates the latest microprocessor technology into the next generation of "programmable" signals with the launch of the Adaptatone product line. 1982 - Edwards begins a planned expansion of hazardous audio and visual signals that will result in the most up-to-date and complete line in the industry. 1984 - The first Edwards piezo-electric signals are introduced, demonstrating the adoption of the latest technology in light duty signaling. 1985 - Edwards begins expanding a planned industrial flasher and pointer products that will result in the highest quality and most complete line in the industry today. 1986 - A new, state-of-the-art photoelectric smoke detector is introduced by Edwards. 1994- Edwards buys the signaling product line from Thomas Industries' Benjamin Division. These new products, previously produced in Sparta, TN, are consolidated at the Pittsfield, Maine plant. 1994- Edwards brought its highly advanced, multi-element sensor technology to the "Commercial" fire alarm market. State-of-the-art production processes have been established in the Pittsfield factory to support the production of these products. 1998 - Edwards offers a new range of stackable visual signals, LED blinking, and steady visual signals and flashes. The new Triliptical stacklite is designed according to customer input. 2005 - Edwards was acquired by General Electric. Edwards merged with Kalatel, Sentrol and EST businesses to become part of GE Security. The company was well placed to be an international leader in video, fire and access control. 2010 - GE Security was acquired by United Technologies Corporation. Edwards Signaling has become part of the Detection and Alert business under UTC Fire & Security. Today. . . With headquarters in Farmington, CT, manufacturing in Pittsfield, ME, distribution in Portland, TN, and Sales and Service locations around the world, it seems like a very long road to the basement of Lungen's jewelery store. Yet many of the different products Edwards manufactures today are direct descendants of gas armature igniters, electric bells, and program systems that went into the design and construction of structures more than a century ago. 860 Series Electronic Horn / Flasher Horn Xenon flash light source Flash speed 60 fpm at 1 meter 100 dB / 90 dB at 10 ft Nexus 105 AC Klaxon Electronic Tone Siren Flasher 5J Xenon beacon Quarter turn fittings for ease of installation 113dB at 1 meter / 103dB at 10ft (max); 105dB at 1 ... Nexus 105 DC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fittings for ease of installation Low inrush current Nexus 110 AC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Low voltage AC variant Three alarm stages Quarter turn fasteners for ease of installation. Nexus 110 DC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fittings for ease of installation Low inrush current (LED ... Nexus 120 AC Klaxon Electronic Tone Siren Flasher 5J Xenon beacon Three alarm stages Quarter turn fasteners for ease of installation 120dB at 1 meter / 110dB at 10ft. (max.) .. Nexus 120 DC Klaxon Electronic Siren Flashlights - Xenon or LED Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fasteners 120dB at 1 meter / 110dB for ease of installation. Nexus 105 AC Klaxon Electronic Tone Siren Light 5J Xenon beacon Quarter turn fittings for ease of installation 113dB at 1 meter / 103dB at 10ft (max); 105dB at 1 ... Nexus 110 AC Klaxon Electronic Tone Siren Flasher 5J Xenon or high efficiency LED Low voltage AC variant Three alarm stages Quarter turn fasteners for ease of installation ... Nexus 120 DC Klaxon Electronic Siren Flashlights - Xenon or LED Flasher 5J Xenon or high efficiency LED Three alarm stages Quarter turn fasteners for ease of installation 120dB at 1 meter / 110dB ... 95 Series Horn-type 85 dB Audible / Visual Flasher AdaptaBeacon Light Duty Strobe Weatherproof Optically designed fresnel lens Built-in, base-mounted horn - 85 dB at 3.05 m (10 feet) Immunity ... 51SIN Series Horn PLC Compatible AdaptaBeacon® Fixed Outdoor Lights Weatherproof Built-in base mounted horn 85 dB at 10 feet (3,05 m) Cast base, ... 51 Series Horn PLC Compatible AdaptaBeacon Flashing Light Flasher Weatherproof Built-in base mounted horn of 85 dB at 10 feet (3.05 m) Cast base, 108 Series Multiple Status LED 3 LED visual signals in one compact housing Option to add an additional module for a fourth light using one. G1R-HDVM-E Genesis Series Electronic Sounder-Beacon, Red, EN54-23 Approved UTC Edwards G1R-VM-E Genesis Series Electronic Flasher, Red, EN54-23 Approved UTC Edwards G1R-HD-E Genesis Series Electronic Siren, Red UTC Edwards G1RB-MP Genesis Series Surface Mount Box for Sounders / Beacons, Red UTC Edwards

  • Alzheimer , Dementia Patients Location Tracking | Platinum Technology

    Prevention of Dementia, Alzheimer, Dementia etc. Patients with Position Tracking Dementia describes a group of symptoms that affect memory, thinking, and social skills. Alzheimer's Disease: Vascular Dementia: Lewy Body Dementia: Frontotemporal Dementia: The most obvious symptom of dementia is forgetting new information. Technological solution to the risks arising in the advanced stages of Alzheimer's Disease Memory problems Difficulty thinking and reasoning Difficulty making decisions, Difficulty finding words, Difficulty in arithmetic operations, Personality and behavior changes, The cases of loss are increasing especially in patients who live alone due to the difficulties in performing the functions that they could easily perform in the past. With our Alzhimer product, which has been developed to minimize the risks that may occur after the patient's disappearance, it is possible to determine the area where the patient is located, to monitor it with the warning signal if it goes beyond the specified limits, and to reach the patient with the keys that call the designated numbers on the device and provide mutual communication. The device can be used for 1 to 3 days without charging. The device can be reached by the specified numbers and calls can be made, and automatic sms can be sent on the device. It is possible to call the numbers determined on the device. In addition, with the digital map support of the device, it can reach the location information. You can report the route information it follows. THE USE OF OUR PRODUCTS HAS BEEN ENDED WITH THE DEVELOPING TECHNOLOGY AND THE SPREAD OF SMART PHONES. MONITORING AND CONTROL FUNCTIONS ARE COMFORTABLE WITH THE APPLICATIONS TO BE INSTALLED ON THE TELEPHONES. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

  • Business Key Management Systems | Platinum Technology

    Business Key Management Systems Key Management Cabinet and Reporting Systems Our key management systems in commercial areas provide rapid response and reporting of the entire circulation when the keys of all areas such as offices, warehouses, archives etc. belonging to the enterprise must be kept under control in all areas from the plaza to the factory in a wide sector from telecommunications to the banking sector. We offer IP-based key management, GSM-based key management and PC-based key management alternatives with several different versions of the system. In this way, you will be able to easily manage the operational management of switches and emergency operations. The system has a designated area for each key and passwords and / or smart cards of all authorized users. The key taken and left by the person who reaches the closet with the authorized password or card is recorded and can be reported when necessary. The system is compatible with all card access control systems. For solutions specific to your project, please contact the platinum technology engineering department. Business Key Management Systems Key Management Cabinet and Reporting Systems Our key management systems in commercial areas provide rapid response and reporting of the entire circulation when the keys of all areas such as offices, warehouses, archives etc. belonging to the enterprise must be kept under control in all areas from the plaza to the factory in a wide sector from telecommunications to the banking sector. We offer IP-based key management, GSM-based key management and PC-based key management alternatives with several different versions of the system. In this way, you will be able to easily manage the operational management of switches and emergency operations. The system has a designated area for each key and passwords and / or smart cards of all authorized users. The key taken and left by the person who reaches the closet with the authorized password or card is recorded and can be reported when necessary. The system is compatible with all card access control systems. For solutions specific to your project, please contact the platinum technology engineering department.

  • İndüksiyon döngü sistemi nedir ?| Platin Teknoloji

    Hearing Impaired Systems with Induction Loop Background Noise in Hearing Impaired Hearing Aids It Is Preventive . The most intense problem experienced by the hearing impaired individuals who have to use headphones, especially in the public space, is the communication problem with the other person due to the background noise created by environmental sounds. Hearing aid manufacturers, who are aware of this problem, have added the T Mode option to most of their devices. What does the T Mode (Telecoil) feature in the hearing aid do? It is used to convert the magnetic sound wave directed through the Telecoil based induction loop units in the hearing aid into audible sound. This way, only you can hear the voice of the person speaking. The general name of the devices that produce audible sound with T-Mode devices: Induction loop. The presence of the induction loop system, which can be used in all areas with full public accessibility regulation, is indicated by the HEADPHONE ICON AND T warning IN A BLUE SQUARE. In such environments, it is sufficient to switch the device to t mode. Where Should Induction Loop System Be Installed? All Public Institutions Banks, Post and Cargo Centers Hotels, Holiday Villages, Hot Springs, Recreation areas Hospitals, Polyclinics Mosques and religious sites Schools, Lecture Halls and Study Centers Cinemas, Performance Halls and Theaters Fair, Exhibition and Art Halls Bank, ticket offices and cash desks, You can get support from our experts for accessibility solutions suitable for your existing structure and architectural elements. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

  • Jam UDP-24  Su Baskını Algılama Dedektörü | Platin Teknoloji

    Jam Aqua Alarm CDBi-485 Zone Detector Module Field detector module for connection to the detection cable. It is made of stainless and ABS plastic. LED on the module and internal alarm sound to give local alarm indication. For connection to the I-Zone Mini control panel. FEATURES 'Aqualarm' CDBi-485 Zone Detector Module, one purpose ABS Box, housing of the electronic circuit. A locking line socket at one end of the module It is installed to allow the connection of the detection cable. The other end is equipped with cloths For connection to the PCB. There is a red LED at the top of the module. The The red LED will flash to indicate an alarm condition. Alarm status and monitoring Single RS485 connection to the I-Zone Mini control panel. The module comes complete with a End-to-End Resistor Plug; Detection cable. Normal operating voltage: 12 volt dc Quiescent Current: <10mA. Per detector. Alarm Current: <100mA. Per detector. Detector Oscillator frequency: 6kHz Recommended connecting cable: 4 Core Cable 22AWG Screened Twisted Pair Belden Ref 8723 Line voltage drop: 1.5 mV / m. Approvals: BS EN ISO 9001: 1994 EMC Directive 89/336 / EEC CD-X Detect Cable Cable detection for all models of the control panel. Constructed of hard-worn Helegaine 66 nylon extinguishing arms providing greater protection against dust and conductive contamination. Locking plugs and sockets for a secure connection. Available in modular lengths of 1, 2, 5 and 10 meters. For connection to Detector Modules and Placement equipment. FEATURE 'Aqualarm' water leak Detection Cable, two flat tinned copper The braids are separated and protected with Helegaine self-extinguishing nylon 66 sheath. This type of configuration protects the sensing centers against dust, others Conductive contamination types and mechanical damage. Cable available In modular lengths of 1, 2, 5 and 10 / m. Each cable is pre-terminated with a male And female locking line plug and socket. Installation Method When a liquid leaking from the piping needs to be protected, the Detection Cable It should be fixed with cable ties under the pipeline, then steam Gasket or thermal protection installed or fixed in the floorboard Just below the pipeline, using appropriate clips or ties. Where protection is required from a liquid leaking from equipment, e.g. water-cooled Computers, chiller factory, air conditioning units etc. Detection Cable for It is fixed on the floor around the equipment. Cable Voltage: No greater than 2 volts from DC Cable diameter: 8 mm Maximum Detection Cable length: Reconstruction System: 50 / m (including bridge cable). ZLM-500: 500 / m (including leader / jumper cable) Operating temperature range: +1 degrees C to +85 degrees Construction: Self extinguishing polymer 66 Monofilaments according to ISO 3795 Braid with straight canned copper sensing veins. Color: Gray / blue Approvals: BS EN ISO 9001: 1994, EMC Directive 89/336 / EEC CE

  • IP Kamera Sistemleri | Platin Teknoloji

    IP Camera Systems IP-based cameras are our future. This data transfer is made over the network or Internet connection. It is ensured that the translated image and sound in a special format are carried in the data. It uses more advanced technologies than traditional systems. It is the optimum solution considering all the costs and operating expenses of the project. IP CCTV has been used for about 10 years. IP cameras have reached a reasonable usable maturity with a number of positive developments such as the development of megapixel sensors, the transportation of camera images in the network at a reasonable size, making them smart with software support, and the competitive conditions of the manufacturers. Benefits of IP Cameras over traditional Analog cameras FLEXIBILITY As long as the IP Camera is connected to the network or internet, it does not need an additional local recording device. Even if there is only one camera in the analog camera system, there is always a need for a special wiring and a local recording device. As the size of the system increases, infrastructure and recording device costs increase. PERFORMANCE IP CCTV systems send megapixel resolution images to the recorder on the network in a suitable format and size and provide images with a size and clarity that can be used as evidence when necessary. Considering that the same clear image can be taken with several analog cameras, it offers solutions with much more economical costs. ANALOGUE Analog CCTV systems are based on PAL analog technology and provide low pixel resolution compared to IP cameras. The evidential images available with a single camera are not limited and clear. SETUP IP CCTV systems run wired or wireless over existing IP networks, this makes cabling IP CCTV systems simple, causing less downtime, reducing the time it takes to install them and minimizing unsightly cables. Setting up an IP-based system is simple for anyone familiar with networking, with intuitive use and evaluation. Simple 1 camera systems only require an IP Camera connected to a network / internet connection, and can then be viewed by a PC using Internet Explorer. If POE (Power over Ethernet) IP cameras and IP networks CCTV cameras are used after even separate power is not required, they can be powered over the network cable. Analog CCTV systems have their own dedicated wiring. Each camera has to monitor the reversing DVR wired or using the RG59 cable or similar Video Signal Cable, and each camera must be connected to a power source. This makes new facilities and additions to existing facilities both expensive and slow to implement. INTEGRATION IP CCTV systems allow to integrate them and coexist on other IP-based systems, such as Access Control and IP Phone Systems, etc.Integration using IP ... Integration also means that different systems work together for example motion picking up a The IP camera will automatically be able to transmit images of this movement to an IP Video Phone. IP systems also allow the direct use of IP-based services as standard, such as sending e-mail or images via FTP. Analog CCTV systems are designed as closed circuit systems, which means they can be easily integrated with Access Control, Intrusion Alarm or other systems found in buildings. Each system requires its own cabling infrastructure, and not every device in each system can communicate with other devices. COST Simple 1 camera systems only require an IP Camera connected to a network / internet connection, and can then be viewed by a PC using Internet Explorer. Our range of CCTV systems offers a very affordable range of cameras, equivalent to analog pricing. You can also work with IP Systems to be much more economical compared to traditional Analog solutions, requiring some time to setup and setup in single and multiple sites. Analog CCTV systems are excellent value for money, and though there is a general consensus that IP CCTV is more expensive, this does not apply to every scenario. Whereas analog CCTV systems are based on legacy technology, IP CCTV represents future technology and infrastructure investment. Platin Technology specialists will provide special solutions to your project for new generation cameras.

  • Araç Tipi Mobil Otomatik Yangın Söndürme Sistemleri | Platin Teknoloji

    Vehicle Type Mobile Automatic Fire Extinguishing Systems It is used in motor marine and land vehicles. Fire is detected with automatic sensors. After the detection, information is given on the screen of the vehicle user, and if the detection is automatically confirmed, the fire extinguishing system is activated. In the extinguishing system, water fog is used by enabling it to make effective extinguishing with a special system. In this way, effective and rapid extinguishing is provided and the protection of passengers and the vehicle is provided. Our automatic mobile extinguishing solutions are easily used in many motor vehicles and cabins, from automobiles to buses, off-road vehicles, military vehicles, yachts to trucks. There is a risk of fire formation and rapid spread due to the fuel used in buses, petrochemicals and materials used in structural manufacturing processes. Engine, fuel tank, exhaust system, vebasto (heating system), air conditioning, braking system (retarder), battery room, electrical installation and cabin fire risk detection and automatic extinguishing solutions are available. WHY IS A VEHICLE FIRE EXTINGUISHING SYSTEM REQUIRED? Fuel and petrochemical substances found in buses and all motor vehicles cause fires to grow in a very short time and prevent large-scale loss of life and property with early intervention. Thanks to rapid intervention, the area is cooled and re-ignited is prevented. It is activated in a short time and takes the fire under control Provides continuous 7 days 24 hours protection HOW DOES THE VEHICLE FIRE EXTINGUISHING SYSTEM WORK? Thanks to the Water Mist nozzle, it produces fine atomized water vapor droplets and covers a very large surface in the fire zone. (400 times according to the classical sprinkler system) It removes oxygen from the fire zone and rapidly absorbs the heat of the fire and cools the area. WHAT ARE THE ADVANTAGES OF VEHICLE FIRE EXTINGUISHING SYSTEM? The Water Foam Mist system is fast and reliable. It uses only 10% of the water amount required by conventional sprinkler systems. Smaller diameter pipes are used. It is suitable for A, B and E (Electricity) classes. The size of the water droplets is 50-100 microns. There are no by-products burning, no toxic fumes. WORKING PRINCIPLES OF VEHICLE TYPE MOBILE FIRE DETECTION AND EXTINGUISHING SYSTEM Vehicle fire extinguishing system consists of two parts as electronic part and mechanical part. Electronic Part: Components of the electronic equipment of the extinguishing system. In the electronic part; EIDA AS400 control panel, detection elements adjusted to certain temperatures, optical smoke detector depending on customer demand. AS400 control panel consists of 3 zones. Zone 1 monitors heat sensors connected to the extinguishing system. Zone 2 monitors heat sensors connected to the detection system. Zone 3 monitors smoke and heat sensors connected to the detection system. and 2. Zone connected sensing elements are located in the engine compartment. Zone 3 is positioned in desired zones (battery box, passenger lounge, driver's cabin) according to customer demand. Sensing elements adjusted to a certain temperature act in case of a possible fire and transmit the signal to the AS400 control panel. When the control panel is activated, it gives warning on the light, sound and digital screen. After the signals come from the 1st zone and the 2nd zone, it activates the solenoid connected to the 1st zone and automatically drains the solution into the engine cabin. In addition, the system on the EIDA AS400 control panel can be activated by the driver with the manual operation option. Mechanical Section: Components of the mechanical equipment of the extinguishing system. In the mechanical part; There are solenoid valves, solution tubes, pipes and fittings, vehicle type nozzles. It becomes active after the fire signal received from the detection elements in the electronic part triggers the solenoid and opens the valve. By applying pressure to the solution of the propellant gas (nitrogen) in the solution tube, the system goes into emptying. The solution is dispersed into the engine compartment in mist form with high pressure with the nozzles that are positioned in various parts of the engine compartment to discharge the solution. It absorbs heat quickly from the environment and displaces oxygen by forming a dense fog layer. As a result, it extinguishes the fire in a short time.

  • Door Type Metal Detectors | Platinum Technology

    Walk Through Metal Search Detectors Door type metal detectors; The simplest and most reliable method that can be taken to prevent possible external threats to businesses is to detect damaging metals on incoming visitors and prevent access to safe areas. Metal detectors have been developed for this purpose. This feature is used in many areas such as store burglar alarm systems and parking sensors in daily life. They have a unique feature that perceives the interior by passing over light materials such as millimetric-waves such as clothes and fabric. Generally, such threats are hidden under a person's clothing and can be easily detected with this feature. It provides easy detection of the target density metals in the area from the top of the head to the bottom of the feet and allows the safety operator to reach the target quickly.

  • Sectoral Solutions | Platinum Technology

    ANSWERS Platin Teknoloji offers solutions across Turkey with the world's leading brands for sectoral risks and security problems specific to projects. Maritime and Marine Services Historical Artifact Restoration Solutions Industrial Facilities Hospitals and Healthcare institutions Business Centers and Plazas Defense industry Banking and finance Automotive Schools and Educational Institutions Solar power plants Merchandising and Retail Mining Schools and Educational Institutions Solar power plants Merchandising and Retail Mining

  • Panic Alarm Button | Platinum Technology

    Panic Alarm Button Panic alarm emergency medical response button systems are installed to quickly transmit information to the security and health units in possible emergencies in closed areas where people are gathered. Established panic alarm buttons are implemented in existing shopping malls without the need for modification. Thanks to the system, which has been applied by Platinum technology experts for many years, it is ensured that the necessary medical assistance can be reached quickly in possible accidents in the shopping mall, and rapid intervention to safety problems is ensured. The system consists of fixed wired / wireless panic buttons. Panic alarm and emergency intervention button works in integration with other existing security and camera systems for fast and effective intervention. Wired health button options Wireless health button options TCP / IP health button options As an option, alarm, malfunction and error information of the whole system is kept. It is possible to follow up all alarms that will come from the field on the central management screen, and monitor possible device malfunctions. It is offered as an option to send detailed alarm information via SMS. It is possible to provide the call automatically for the health, security unit and ambulance in charge of the enterprise. Friday, February 26, 2016 Official newspaper Number: 29636 From the Ministry of Customs and Trade: REGULATION ON SHOPPING MALLS ARTICLE 8 - (1) An emergency medical response unit of at least twenty square meters is established in an easily accessible place of the shopping center in order to provide the first response in emergency medical situations and to provide referral to the nearest hospital in case of need. (2) At the entrance of the emergency medical response unit, there is a letter and sign of "Emergency Medical Response Unit". The location of the emergency medical response unit is indicated by signposts. (3) At least one emergency medicine technician or emergency medicine technician in the shopping center with a sales area of ​​less than twenty thousand square meters, at least one emergency medicine technician and at least one emergency medicine technician or emergency medicine technician in the shopping center with a space of twenty thousand to fifty thousand square meters, Two emergency medical technicians, at least one emergency medical technician and emergency medicine technician in the shopping center with a sales area of ​​fifty thousand to one hundred thousand square meters, and at least one emergency medical technician and medical doctor in the shopping center with a sales area of ​​one hundred thousand square meters or more. (4) First aid materials and equipment in the quality and quantity determined by the Ministry of Health are kept in the emergency medical response unit. (5) A sufficient number of emergency medical status buttons are placed in visible parts of the common use areas in the shopping center and retail businesses larger than four hundred square meters in order to communicate with the emergency medical response unit. (6) The services envisaged in this article may also be provided by purchasing services from private healthcare providers. You can get support from Platinum Technology experts for panic button solutions that enable all disabled and non-disabled individuals to quickly access help from the relevant unit in case of a possible health, security, etc. panic situation.

  • Brands | Platinum Technology

    Brands We offer solutions with a very wide supplier network consisting of the world's leading brands in their field, Turkey-wide Dealer, Solution Partner and Distributor brands.

  • vesda xtralis Hava örnekleme dedektörü Türkiye'de | platinteknoloji

    VESDA OSID New generation Beam Detector Revolutionizing very early warning smoke detection with VESDA, the company has reinvented smoke detection for outdoor areas with Outdoor Smoke Imaging Detection (OSID). OSID by Xtralis provides reliable, cost-effective smoke detection for open areas where fire detection presents unique challenges and very early warning is not always a priority. Solutions for all areas with complex high ceilings with the new generation Beam detector Using imaging technology based on the CMOS Imager, the OSID series offers fast setup and superior detection performance that cannot be achieved using a single photo receiver. A CMOS imager is equivalent to hundreds of thousands of photocells. Automatic setup reduces setup time from hours to minutes. CMOS imagers locate detection targets (Transmitter or Reflector) and lock onto it, eliminating building motion issues. The CMOS imager also allows to minimize drastically false alarms caused by foreign body ingress and sunlight saturation. In its simplest configuration, OSID-R (Reflector) uses a viewer and a reflector. It works according to the principle of dimming the light using infrared rays and performs intelligent analysis at the pixel level of its reflector, which offers superior performance. Power and connection occur only in the imager, and the OSID-R only requires a single standard reflector on the opposite wall (not a larger reflector the farther you go). ​ Alongside this stepping model is OSID-DE (Double-ended), which uses a similar CMOS sensor with wired or battery-operated transmitter(s) roughly aligned on the opposite wall within the protected area. The transmitter sends both infrared and ultraviolet coded light signals to the imager. The innovative use of dual light frequencies in an open path device allows OSID-DE to distinguish between real smoke and other solid objects. It offers high resistance to sudden and temporary clouds of dust and vapor, significantly reducing false alarms. The OSID range of outdoor smoke detectors offers a great package for reliable smoke detection in large or open areas. Using CMOS imaging technology, OSID not only provides reliable smoke detection, but is designed for fast setup and reliable operation throughout the detector's lifetime. Installers no longer face lengthy and costly setup processes and callbacks; and end users are no longer bothered by annoying or false alarms about building movement; dust or beam interruption. OSID offers a reliable alternative to heat or flame detectors, which typically start much later in the fire development cycle. Osid Beam Detector Product Options Headunits Xtralis OSI-10 Imager 7° Horizontal, 4° Vertical Shield, min. 30m, max 150m range, use only with standard power emitter, 8mA@1xemitter, 10mA@7xemitter ​ Xtralis OSI-90 Imager 80° Horizontal, 48° Vertical Protection, min. 6m, max 34m range (with standard powerful emitter), min. 12m, max 68m range (with high power emitter) ​ Reflectives Xtralis OSE-SP-01 Standard Power Emitter with Internal Battery Xtralis OSE-SPW Standard Power Emitter, 24V DC External Powered Xtralis OSE-HPW High Power Emitter, External Power Input, 800mA@24V DC Xtralis OSE-HP-01 High Power Emitter with Internal Battery

  • vesda xtralis Hava örnekleme dedektörü Türkiye'de | platinteknoloji

    VESDA OSID New generation Beam Detector Revolutionizing very early warning smoke detection with VESDA, the company has reinvented smoke detection for outdoor areas with Outdoor Smoke Imaging Detection (OSID). OSID by Xtralis provides reliable, cost-effective smoke detection for open areas where fire detection presents unique challenges and very early warning is not always a priority. Solutions for all areas with complex high ceilings with the new generation Beam detector Using imaging technology based on the CMOS Imager, the OSID series offers fast setup and superior detection performance that cannot be achieved using a single photo receiver. A CMOS imager is equivalent to hundreds of thousands of photocells. Automatic setup reduces setup time from hours to minutes. CMOS imagers locate detection targets (Transmitter or Reflector) and lock onto it, eliminating building motion issues. The CMOS imager also allows to minimize drastically false alarms caused by foreign body ingress and sunlight saturation. In its simplest configuration, OSID-R (Reflector) uses a viewer and a reflector. It works according to the principle of dimming the light using infrared rays and performs intelligent analysis at the pixel level of its reflector, which offers superior performance. Power and connection occur only in the imager, and the OSID-R only requires a single standard reflector on the opposite wall (not a larger reflector the farther you go). ​ Alongside this stepping model is OSID-DE (Double-ended), which uses a similar CMOS sensor with wired or battery-operated transmitter(s) roughly aligned on the opposite wall within the protected area. The transmitter sends both infrared and ultraviolet coded light signals to the imager. The innovative use of dual light frequencies in an open path device allows OSID-DE to distinguish between real smoke and other solid objects. It offers high resistance to sudden and temporary clouds of dust and vapor, significantly reducing false alarms. The OSID range of outdoor smoke detectors offers a great package for reliable smoke detection in large or open areas. Using CMOS imaging technology, OSID not only provides reliable smoke detection, but is designed for fast setup and reliable operation throughout the detector's lifetime. Installers no longer face lengthy and costly setup processes and callbacks; and end users are no longer bothered by annoying or false alarms about building movement; dust or beam interruption. OSID offers a reliable alternative to heat or flame detectors, which typically start much later in the fire development cycle. Osid Beam Detector Product Options Headunits Xtralis OSI-10 Imager 7° Horizontal, 4° Vertical Shield, min. 30m, max 150m range, use only with standard power emitter, 8mA@1xemitter, 10mA@7xemitter ​ Xtralis OSI-90 Imager 80° Horizontal, 48° Vertical Protection, min. 6m, max 34m range (with standard powerful emitter), min. 12m, max 68m range (with high power emitter) ​ Reflectives Xtralis OSE-SP-01 Standard Power Emitter with Internal Battery Xtralis OSE-SPW Standard Power Emitter, 24V DC External Powered Xtralis OSE-HPW High Power Emitter, External Power Input, 800mA@24V DC Xtralis OSE-HP-01 High Power Emitter with Internal Battery

  • Panic Alarm Button | Platinum Technology

    Panic Alarm Button Panic alarm emergency medical response button systems are installed to quickly transmit information to the security and health units in possible emergencies in closed areas where people are gathered. Established panic alarm buttons are implemented in existing shopping malls without the need for modification. Thanks to the system, which has been applied by Platinum technology experts for many years, it is ensured that the necessary medical assistance can be reached quickly in possible accidents in the shopping mall, and rapid intervention to safety problems is ensured. The system consists of fixed wired / wireless panic buttons. Panic alarm and emergency intervention button works in integration with other existing security and camera systems for fast and effective intervention. Wired health button options Wireless health button options TCP / IP health button options As an option, alarm, malfunction and error information of the whole system is kept. It is possible to follow up all alarms that will come from the field on the central management screen, and monitor possible device malfunctions. It is offered as an option to send detailed alarm information via SMS. It is possible to provide the call automatically for the health, security unit and ambulance in charge of the enterprise. Friday, February 26, 2016 Official newspaper Number: 29636 From the Ministry of Customs and Trade: REGULATION ON SHOPPING MALLS ARTICLE 8 - (1) An emergency medical response unit of at least twenty square meters is established in an easily accessible place of the shopping center in order to provide the first response in emergency medical situations and to provide referral to the nearest hospital in case of need. (2) At the entrance of the emergency medical response unit, there is a letter and sign of "Emergency Medical Response Unit". The location of the emergency medical response unit is indicated by signposts. (3) At least one emergency medicine technician or emergency medicine technician in the shopping center with a sales area of ​​less than twenty thousand square meters, at least one emergency medicine technician and at least one emergency medicine technician or emergency medicine technician in the shopping center with a space of twenty thousand to fifty thousand square meters, Two emergency medical technicians, at least one emergency medical technician and emergency medicine technician in the shopping center with a sales area of ​​fifty thousand to one hundred thousand square meters, and at least one emergency medical technician and medical doctor in the shopping center with a sales area of ​​one hundred thousand square meters or more. (4) First aid materials and equipment in the quality and quantity determined by the Ministry of Health are kept in the emergency medical response unit. (5) A sufficient number of emergency medical status buttons are placed in visible parts of the common use areas in the shopping center and retail businesses larger than four hundred square meters in order to communicate with the emergency medical response unit. (6) The services envisaged in this article may also be provided by purchasing services from private healthcare providers.

  • Aritech Yangın İhbar Butonları | Platin Teknoloji

    Aritech Fire Detection, Warning and Alarm UTC Arıtech, one of the flagship brands of UTC Carrier Fire & Security 'family, is in Turkey !! Platin Teknoloji service difference Why should the Aritech fire detection system be preferred? Fire detection and alarm system is the most important protection solution for the safety of life and property in all businesses, whether small or large. A failure in the system can pose a danger at a level that can endanger the entire investment. Knowing these problems and responsibilities, Aritech produces solutions with its long years of experience and products in accordance with world standards. Helps protect investments and human life. It has combined this solution partnership with platinum technology expertise in Turkey. Thanks to fast installation and commissioning, easy maintenance and outstanding modern design, 2X Series fire panels are appreciated by technical personnel, installation personnel, architects and investors. Aritech Fire Alarm Systems Distinctive Features Simple and convenient front panel control Fast system setup and configuration Increased automatic programming feature • Undo last changes feature Offline programming and ability to upload configuration file to USB device Easily configurable preferred cards and modules Remote maintenance and error detection over TCP / IP Up to 72 hours of standby time Graphical EN54 compliant icon supported LCD display Easy to change language options Surface / flush * / 19 ”rack * mounting It offers superior performance features from single panel applications to applications requiring small / medium sized networks. Aritech 2X-Intelligent Analogue Addressable Fire Detection Panel 2X-F1-19 Intelligent Addressable Fire Alarm Panel - 1 loop (Turkish) 2X-F2-19 Intelligent Addressable Fire Alarm Panel - 2 loops (Turkish) 2X-FR-19 Intelligent Addressable Fire Repetition Panel (Turkish) 2X-LB Loop expansion board - 2 loops 2010-2-NB Network Card 2X-ZI-20 LED Indicator Screen - 20 Zone 2X-ZI-40 LED Indicator Screen - 40 Zone Optical Smoke Detector DP2061N Addressable Optical Smoke Detector, Double LED, Remote Output DP2071 Addressable Optical Smoke Detector, 7-segment display, Remote Output Heat Detector DT2063 Addressable Heat Detector, Double LED, Remote Output DT2073 Addressable Heat Detector, 7-segment display, with Remote Output Combined Detector DP2061T Addressable Combined Detector, Optical / Heat Detector Base DB2002 Standard Detector Base, 4 Terminals, Grounded - 100mm DB2016 Insulator Base Sounder Detector Base AS2368CAP-R Locking Cover for DB2368 Sounder Base, Red AS2368CAP-W Locking Cover for DB2368 Sounder Base, White LED Indicator AI672 LED Indicator AI673 LED Indicator with Buzzer Fire Alarm Button DM2010 Addressable Manual Call Point, Red, Surface Mount (Glass Included) DM2010E Addressable Outdoor Fire Alarm Button, Red, Surface Mount (Glass Included), IP67 Control-Monitoring (Input / Output) Modules IO2014C Addressable Control Module - 4 Inputs (Including mounting box) IO2031C Addressable Control Module - 2 Inputs / 1 Output (Including mounting box) IO2032C Addressable Control Module - 2 Inputs / 2 Outputs (Including mounting box) IO2034C Addressable Control Module - 4 Inputs / 4 Outputs (Including mounting box) IU2050C Addressable Control Module - 1 Input (Including mounting box) IU2055C Addressable Control Module - 2-wire Zone Monitoring (Including mounting box) IU2080C Addressable Control Module - Siren (Including mounting box) IO-2BOX Assembly box ISM-95 Isolator Module (Including mounting box) Loop Powered Siren and Warning Equipment AS2363 Loop Powered Siren, 32 Different Tones, Shallow Base, Red AS2363W Loop Powered Siren, 32 Different Tones, Shallow Base, White AS2364 Loop Powered Siren, 32 Different Tones, Deep Base, Red AS2364W Loop Powered Siren, 32 Different Tones, Deep Base, White AS2366 Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, Red AS2366W Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, White AS2366WY Loop Powered Sounder / Beacon, 32 Different Tones, Shallow Base, White / Amber AS2367 Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, Red AS2367W Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, White AS2367WY Loop Powered Sounder / Beacon, 32 Different Tones, Deep Base, White / Amber

  • Ziton Fire Detection and Alarm Equipment | Platinum Technology

    Ziton Fire Detection , Warning ve Alarm Systems Ziton Fire Alarm Systems Features that Make a Difference; • Simple and convenient front fire control paneli and • Fast Ziton Fire detection system installation and configuration • Automatic fire scenarios and programming feature • Ability to undo recent changes • Offline programming of the fire panel and uploading the configuration file to the USB device • Preferential cards and modules that can be easily integrated into the Ziton fire detection panel. • Remote maintenance and fault detection of the fire alarm panel over TCP/IP • In case of power cuts yang panel standby time up to 72 hours • Graphical EN54 compliant LCD display with icon support • Ziton-specific language options that can be easily changed from the fire panel • Surface / flush * / 19” rack* mounting Superior performance Features from single control panel applications to applications requiring small/medium network Ziton fire detection and alarm systems, one of the leading brands of UTC Carrier Fire & Security; UTC Ziton is offered throughout Turkey with the widespread network of Platinum technology. In addressable systems, there are optical, heat and combined fire detection detectors, input and output modules, alarm buttons, addressable sirens that can be connected to the loop lines to which the detection elements are connected. The number of the loop line and the wiring distance depend on the panel used. 127 addressable fire detection equipment can be connected to each loop line. Sensing elements in the loop can be divided into software regions, and each sensing element can be individually perceived by the panel thanks to the addressing software it contains. In other words, when any detector detects, the location of the detector can be determined individually on the panel or on the pc where the projects of the building, which can be used optionally, are loaded. Conventional systems and addressable systems are selected and sized according to their application locations. Ziton, Kilsen, Aritech Series from UTC Carrier fire detection brands, Turkey-wide system solutions of high-tech equipment are provided by Platin Technology and distributors, engineers and technical teams with more than 20 years of project design and application experience in the sector. Fire Alarm Systems Distinctive Features ziton Simple and convenient front panel control Fast system setup and configuration Increased automatic programming feature • Undo last changes feature Offline programming and ability to upload configuration file to USB device Easily configurable preferred cards and modules Remote maintenance and error detection over TCP / IP Up to 72 hours of standby time Graphical EN54 compliant icon supported LCD display Easy to change language options Surface / flush * / 19 ”rack * mounting Superior performance from single panel applications to applications requiring small / medium sized networks Advantages of Ziton series addressable systems 1- In Interactive Addressable systems, clear information of the place where the alarm, malfunction etc. information comes from can be reached. In conventional systems, region (floor) information comes. The net location of the detector must be checked for the region. 2- In addressable systems, alarm, error, loss, malfunction and calibration information of the detectors are displayed on the panel as a point. 3- In addressable systems, 127 equipment can be operated on each cable line. In conventional systems, this number is limited to 20-25 detectors. 4- In addressable systems, in the problem of the wiring line, the system provides access to information about the location of the continuing problem. In conventional systems, the part after the line is completely disabled. 5- Equipments such as input module, output module, siren module etc. from addressed systems can operate over the loop line. In conventional systems, general alarm and error information can be received from the panel. 6- In addressable systems, wide range of alarm scenarios that will be activated in case of fire can be applied. In summary, it offers solutions in large and medium-scale projects with low infrastructure, operating and initial investment costs thanks to its modular structure and technology. Ziton ZP3 Series Network Control Panels ZP3 control panels have 1, 2 and 4 loop capacity ZP3 series fire alarm panels that can be networked with each other, each supporting 127 x XX addressable devices. Ziton ZP3 fire alarm panels are compatible with both ZX series algorithm based, interactive and ZP series analog addressable field elements. These panels also have interfaces to fulfill the necessary network communication for medium and large-scale systems, fiber-optic and IP-based communication facilities. Repeater panels compatible with ZP3 control panels, computerized graphic monitoring software and interfaces used for integration with automation systems are also available as optional. Additional input / output circuits can be created with the cards that can be added to the panels, and panel type printers can be connected. Ziton MODULA Stand-Alone Control Panels MODULA series control panels have a structure that can be expanded modularly, starting from 1 loop to 8 loops, up to 1016 address capacity in total. It also supports conventional sensing circuits up to 48 zones. It is compatible with analog addressable field elements called ZP series. With its large LCD screen, alarm zone LEDs and easy programming alternatives, it fully meets all fire detection needs of medium and small scale applications. Multi-Sensor Algorithm Based, Interactive Fire Detectors ZX 832 algorithm-based, interactive fire detectors use their microprocessor and algorithms to generate alarm decisions depending on the smoke and temperature level coming from their sensors. ZX832 Detectors do not need to send any analog value to the panel and evaluate it there by generating the alarm decision completely in-house. Thanks to the algorithms used, false alarms are prevented and possible real alarms can be detected faster. Single and Multi Sensor Ziton Analog Addressable Fire Detectors ZP3 and MODULA are compatible with Ziton control panels, optical smoke and ionization smoke detectors, as well as multi-sensor detectors combined with optical smoke and temperature sensors, and point temperature detectors that can be programmed as both constant temperature and temperature rise rate. The analog values ​​measured by the detectors are continuously sent to the control panel through the detection lines, and alarm and failure situations are decided by the algorithms installed in the control panels. Addressable Ziton Input, Output and Control Modules Addressing conventional type detectors and buttons, monitoring modules for monitoring the alarm and fault signals of smoke control devices such as fans and dampers, sprinkler systems, as well as audible / illuminated alarm devices, audible evacuation systems, smoke control devices and other building control systems to the specified fire scenarios Output modules and short circuit isolator modules required for proper activation are included in the analog addressable product group. Ziton modules are specially designed for in-panel rail mounting, providing ease of installation and assembly with their small dimensions. Ziton Addressable Audio / Light Warning Devices Addressable sound / light alarm devices are compatible with the addressable loop lines of the ZP3 and MODULA control panels. 124 of these addressable devices, which are capable of producing high sounds despite their low current consumption, can be connected to the same loop line together with detectors and modules and they can perform sufficient warning operations. One of the most important features of these devices is that they can be activated individually and they do not require additional cables for feeding. Addressable warning devices can also perform self-test procedures on their own, thanks to the test microphone inside. Intrinsically Safe Ziton Detector, Button and Modules One of the preferred methods for safe fire detection in industrial environments with flammable and explosive materials is applications using Intrinsically Safe (IS) devices. ZP3 and MODULA series panels offer a complete range of interfaces that can be connected to addressable loop lines, galvanic barrier, intrinsically safe single and multi-sensor detectors, button and input modules. Intrinsically safe barriers, detectors and audible / light warning devices have ATEX certificate for ia class explosive atmospheres. Our Ziton Fire Detection and Alarm Product range ZP3 serisi panelleri bir süredir seri üretimi sonlandırıldığı için mevcut projelerde yedek parça şeklinde tedarik edilmektedir. ​ Ziton ZP2 Serisi Adreslenebilir Yangın Alarm Kontrol Panelleri ZP2-F1-19 Analog Adreslenebilir Yangın Alarm Kontrol Paneli - 1 Loop, 127 Adres Kapasitesi, Grafik LCD Ekran, 2 Programlanabilir Sesli Alarm Çıkışı, Güç Kaynağı ve Akü Şarj Ünitesi ile birlikte - Büyük Kabin, Türkçe Menü ZP2-F1-S-19 Analog Adreslenebilir Yangın Alarm Kontrol Paneli - 1 Loop, 127 Adres Kapasitesi, Grafik LCD Ekran, 2 Programlanabilir Sesli Alarm Çıkışı, Güç Kaynağı ve Akü Şarj Ünitesi ile birlikte- Küçük Kabin, Türkçe Menü ZP2-F2-19 Analog Adreslenebilir Yangın Alarm Kontrol Paneli - 2 Loop, 254 Adres Kapasitesi, Grafik LCD Ekran, 2 Programlanabilir Sesli Alarm Çıkışı, Güç Kaynağı ve Akü Şarj Ünitesi ile birlikte - Büyük Kabin, Türkçe Menü ZP2-F4-19 Analog Adreslenebilir Yangın Alarm Kontrol Paneli - 4loop , 508 Adres Kapasitesi, Grafik LCD Ekran, 2 Programlanabilir Sesli Alarm Çıkışı, Güç Kaynağı ve Akü Şarj Ünitesi ile birlikte - Büyük Kabin, Türkçe Menü ​ Ziton ZP Serisi Kontrol Panelleri için Giriş/Çıkış Opsiyon Kartları 2010-2-NB ZP2 Analog Adreslenebilir Yangın Alarm Panelleri için Network Kartı ZP2-LB ZP2-F2-S için Genişletme Kartı, 2 Loop, 254 Adres Kapasitesi, 4 Programlanabilir Sesli Alarm Çıkışı ZP2-ZI-20 ZP2 Paneller için Zone LED Göstergesi - 20 zon için ZP2-ZI-24 ZP2-S Paneller için Zone LED Göstergesi - 24 zon için ZP2-ZI-40 ZP2 Paneller için Zone LED Göstergesi - 40 zon için 2010-2-232-KIT ZP2 Panelleri için RS232 Kit ( Yazıcı Bağlantısı için Kullanılmaktadır.) ​ Ziton ZP2 Serisi Kontrol Panelleri için Grafik İzleme Yazılımı ve Lisanslar ATS8600 Grafik İzleme ve Kontrol Yazılımı, Başlangıç Paketi: maksimum 2 cihaz için ATS8605 Genişletme Lisansı (ATS8600 için) ATS8610 Grafik İzleme ve Kontrol Yazılımı, Business Paketi: maksimum 25 cihaz için ATS8640 Genişletme Lisansı (ATS8645 Eklenebilmesi için) ATS8645 İlave Yazılım (ilave edilecek ZP2 Panel Sayısı Kadar Kullanılmalıdır.) 2010-2-PAK-900 ZP2 Paneller için Apollo Driver 2010-2-PAK-NET128 Ziton Network Genişletme Lisansı - 32 nodes / 128 loops 2010-2-PAK-NET256 Ziton Network Genişletme Lisansı - 64 nodes / 256 loops 2010-2-PAK-RMBN ZP2 Panelleri için Haberleşme Arabirim Lisansı - BACnet IP 2010-2-PAK-RMMB ZP2 Panelleri için Haberleşme Arabirim Lisansı - Modbus IP 2010-2-PAK-RMSDK Adreslenebilir Yangın Panel Aksesuarı, Uzak Kontrol ve IP üzerinden SDK Paylaşımı ​ Tüm Türkiye Geneli UTC Ziton Yangın Algılama ve Alarm Panelleri Platin Teknoloji'de .

  • Occupational Health and Safety | Platinum Technology

    ELECTRONIC SOLUTIONS FOR WORKER HEALTH AND SAFETY With the expertise of the World's Leading Brands Platinum Technology, We Offer Solutions in Projects throughout Turkey. Flammable, Explosive Gas Detection Gases used in industry or generated during manufacturing or gases generated in storage areas that are concentrated above the risk limits pose a risk in terms of worker health and workplace safety. You can get support from Platin Technology experts for detailed information and solution. More information Toxic Chemical Detection and Alarm Toxic chemicals that are used in industrial areas due to the process or that arise with the process pose a risk. All substances that cause serious damage and death to living creatures and harm human health when inhaled, exposed or contacted are defined as "Toxic Gas". You can get support from Platin Technology experts for detailed information and solution. More information Industrial Fire Detection Platin Technology specialists offer solutions for the detection and early detection of fire in industrial facilities, with detailed analysis of the structure of the enterprise, and detecting equipment with the lowest error rate. More information Panic Button Emergency Assistance System Panic alarm, emergency medical response button and communication systems are installed in industrial facilities to quickly transmit information to security and health units in possible emergencies. Established panic alarm buttons are implemented in accordance with the existing infrastructure without requiring any modifications. More information isg kamera üzerindn analiz ve algılama yazılımı

  • Otomatik Sesli Işıklı Uyarı ve Konuşma | Platin Teknoloji

    Automatic Voice Light Alert and Speaking Event analysis can be performed more efficiently and with high accuracy with new generation IP cameras and software integrated with them. Especially in perimeter security applications, cameras can monitor border-area violations with existing fence and virtual fence applications. The camera saw the entrance to the area, the software detected a violation. So how should be intervened? Especially in the protected areas, it is not possible to reach the suspects after their inward or outward movements during the physical intervention to the area where the violation took place. Given that the primary purpose of security systems is to deter. The scenario should be as follows. The camera saw the entrance to the area, The software has detected a violation. The camera has activated a voice announcement and light warning module in its area. '' You are in the forbidden zone, leave this place immediately '' made the announcement. The suspect quickly left the area, the announcement was automatically silenced, The suspect does not leave the area, the activity is increased by making a connection to the device in the field with CCTV software and making live announcements. Security will be ensured. ADVANTAGES Different automatic voice announcements according to the scenario Manual / live voice announcements Compatible with cameras with brand-independent 8 Ohm speaker connection Does not require additional cabling infrastructure / amplifier etc. It is not affected by power cuts. Suitable for outdoor conditions Active protection support with illuminated additional warnings You can get support from Platin Technology experts for sound and light warning solutions that can be integrated with the existing IP Camera system and software specific to your Perimeter Security Project.

  • Talentum Flame Detector | Platinum Technology

    Inventor of the Talentum Flame Detector The Talentum® story began by the father of inventor Andrew Broadbent; A textile supervisor felt that the local fire service had become a fixture in his workplace. Traditional smoke detectors could not cope with the dusty mill environment, resulting in frequent false alarms. This posed a real risk of distracting the fire department from emergencies or creating a “cry wolf” scenario where the alarm would not be taken seriously. Andrew knew that the first evidence of a fire in a textile warehouse was not smoke, but sparks, and thus he would develop the world's first rearview infrared device for flame detection. Being able to detect a jitter in 27 milliseconds, it also becomes the fastest in the world. Such a fast detection and such a respected Talentum® solution, Project BLOODHOUND setting a new land speed record of 1000mph chose Talentum® as the flame detection device. . Like the BLOODHOUND Project team, we are assertive and do not believe we are standing still. Talentum® is constantly evolving and new features such as the Test Air Purification kit for exceptionally high dust environments are already planned. With Talentum®, you are one step ahead at risk and your sites and assets are kept safe. You can get support from platinum technology experts for Talentum flame detector solutions in Turkey. Features Can be used for indoor and outdoor areas Flame-proof, explosion-proof and high ambient temperature options Internal self-testing capability giving highest immunity to spurious flame sources Detects invisible flames from fuels such as hydrogen and other inorganic fuels. Immunity to the effects of wind, drafts and sunlight Where Does Talentum® Do? Talentum® is perfect for environments and industries where steam, smoke and dust are common. Agriculture Automotive Airplane Hangers Aviation Repair Mattress Fillers Biomass Storage and Processing Chemical plants Coal Handling and Milling Compressor Stations Dryers Dust Collection and Filtering Engine Rooms Felt manufacturing Fuel Loading Racks Generators High Voltage Equipment LNG / LPG Production Military and Marine Nuclear and Non-Nuclear Power Plants petrochemical Pharmaceutical Production Printing Refineries Spray Booths Storage tanks Tunnels Waste Recycling Woodworking An optical flame detector detects the heat and light generated by a flame. Using infrared (IR) sensing technology, flames can be detected through elements such as dust, steam and smoke; They are also immune to wind or draft influences. With the addition of an ultraviolet (UV) sensor, a flame detector becomes highly immune to false signals such as sunlight. Optical sensors inside the detector receive IR and / or UV radiation emitted by flames. The processor inside the detector analyzes the optical sensor signal waveforms and determines whether they represent flames and if so accepts them. If the signals do not match the internal algorithms for flames, they are considered to be false sources and rejected. Talentum® Dual IR Talentum® Triple IR Talentum® UV / Dual IR Product Lifetime Our products protect people and property around the world from the risk of fire, it is a responsibility we take very seriously. Talentum recommends replacing routine detectors after 10 years.

  • Engelli Yardım Çağrısı Buton Sistemi | Platin Teknoloji

    Disabled Help Call Button System We offer wireless disabled assistance and call system solutions that will increase the comfort of life of individuals who need help due to reasons such as the disabled, elderly, sick, etc., and that will enable them to reach and get help quickly in the difficulties and problems they experience due to the architectural and physical conditions of the buildings. All areas where people live collectively and open to the public; Hospitals, health centers, etc. Bank, Post Office, Store, Business centers, plaza, shopping mall, shop etc. shopping areas Station, Station, airport etc. main entrance doors of areas, garage entrances, restricted areas Various buildings belonging to public service institutions We offer solutions that enable the staff to reach and ask for help in case of physical difficulties at the entrances of the areas, elevators, disabled ramps, parking areas, etc. You can reach platinum technology experts for barrier-free living solutions. General Specifications Audio output 85dB Piezo buzzer LED indicator Wireless communication Long battery life Working frequency 433.92 Mhz Suitable for external environment use Bi-directional operation Siren LED flasher and wireless call button Microprocessor controlled Surface mount Compliant with EN 300 220-1 and EN 301 489-3 standards FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

bottom of page