top of page

Site Search Results

254 items found for ""

  • Duman Tableti Nedir | Platin Teknoloji

    What is Smoke Tablet? Smoke tablet offered as a solution for ventilation installation, chimney, sealing, odor test and smoke evacuation equipment testing that require artificial smoke in the environment. It has a structure that will provide the necessary intense smoke quickly. . With the intense smoke obtained, impermeability and device performance tests can be performed easily. . Smoke Tablet / Cartridge / Generator: It defines the test apparatus produced for chimney draft test, which emits smoke without creating flame and soot when burned. Smoke Tablets 45 second smoke tablet (Available in Stocks) 10 cartridges / box Smoke Color: white weight approx: 3 g / cartridge Size approx: 32 x Ø 14 mm Smoke Volume approx: 2,5 m³ Burning time approx: 45 sec. Compliant to BS 5440-1, Ds 675, Test Method ISO 5659-2. Use for testing: Smoke Alarms, Air Filters, Hoods, Air Balancing, Fans, Photography, Special Effects and much more. Not used in sensitive environments, contains large amounts of chloride 90 second smoke tablet (Special order) Allows to produce smoke in use 150 second smoke tablet (Special order) Allows to produce smoke in use 240 second smoke tablet (Special order) Allows to produce smoke in use 300 second smoke tablet (Special order) Allows to produce smoke in use Smoke Cartridges features Cartridges made of environmentally friendly plastic. Moisture-sealed smoke pellets. Reinforced base for minimal heat transfer. There are only smoke pellets made of high-content chemicals. It is guaranteed for 3 years from the date of delivery. Contains no zinc, rubber powder or mothballs. More than 250 security tests have been carried out. There is a warranty mark on the bottom. Comes in a consumer pack or large pack. Fume Tablet Usage Areas Energy Saving insulation test Ventilation Channel Test Draft Test Leak detection Security tests Negative Pressure Chambers Positive Pressure Rooms Fume Hoods Exhaust fans Stage and Screen Effects Photo Effects Air Balancing test Filtration Test Dust Removal Systems Fire and Smoke Alarm Test Poultry and Livestock Education Heat Exchangers Tanks and Piping Kitchen Hoods Electronic Air Filters Asbestos Reduction Radon Reduction Mechanical system risk management. Waste Treatment Systems

  • Duman Tableti ile Soba Bacası Testi | Platin Teknoloji

    Smoke Test Tablet Smoke tablet offered as a solution for ventilation installation, chimney, sealing, odor test and smoke evacuation equipment testing that require artificial smoke in the environment. It has a structure that will provide the necessary intense smoke quickly. . With the intense smoke obtained, impermeability and device performance tests can be performed easily. . Smoke Tablet / Cartridge / Generator: It defines the test apparatus produced for chimney draft test, which emits smoke without creating flame and soot when burned. Smoke Tablets 45 second smoke tablet (Available in Stocks) 10 cartridges / box Smoke Color: white weight approx: 3 g / cartridge Size approx: 32 x Ø 14 mm Smoke Volume approx: 2,5 m³ Burning time approx: 45 sec. Compliant to BS 5440-1, Ds 675, Test Method ISO 5659-2. Use for testing: Smoke Alarms, Air Filters, Hoods, Air Balancing, Fans, Photography, Special Effects and much more. Not used in sensitive environments, contains large amounts of chloride 90 second smoke tablet (Special order) Allows to produce smoke in use 150 second smoke tablet (Special order) Allows to produce smoke in use 240 second smoke tablet (Special order) Allows to produce smoke in use 300 second smoke tablet (Special order) Allows to produce smoke in use Smoke Cartridges features Cartridges made of environmentally friendly plastic. Moisture-sealed smoke pellets. Reinforced base for minimal heat transfer. There are only smoke pellets made of high-content chemicals. It is guaranteed for 3 years from the date of delivery. Contains no zinc, rubber powder or mothballs. More than 250 security tests have been carried out. There is a warranty mark on the bottom. Comes in a consumer pack or large pack. Fume Tablet Usage Areas Energy Saving insulation test Ventilation Channel Test Draft Test Leak detection Security tests Negative Pressure Chambers Positive Pressure Rooms Fume Hoods Exhaust fans Stage and Screen Effects Photo Effects Air Balancing test Filtration Test Dust Removal Systems Fire and Smoke Alarm Test Poultry and Livestock Education Heat Exchangers Tanks and Piping Kitchen Hoods Electronic Air Filters Asbestos Reduction Radon Reduction Mechanical system risk management. Waste Treatment Systems

  • Duman Tableti | Platin Teknoloji

    Smoke Test Tablet Smoke tablet offered as a solution for ventilation installation, chimney, sealing, odor test and smoke evacuation equipment testing that require artificial smoke in the environment. It has a structure that will provide the necessary intense smoke quickly. . With the intense smoke obtained, impermeability and device performance tests can be performed easily. . Smoke Tablet / Cartridge / Generator: It defines the test apparatus produced for chimney draft test, which emits smoke without creating flame and soot when burned. Smoke Tablets 45 second smoke tablet (Available in Stocks) 10 cartridges / box Smoke Color: white weight approx: 3 g / cartridge Size approx: 32 x Ø 14 mm Smoke Volume approx: 2,5 m³ Burning time approx: 45 sec. Compliant to BS 5440-1, Ds 675, Test Method ISO 5659-2. Use for testing: Smoke Alarms, Air Filters, Hoods, Air Balancing, Fans, Photography, Special Effects and much more. Not used in sensitive environments, contains large amounts of chloride 90 second smoke tablet (Special order) Allows to produce smoke in use 150 second smoke tablet (Special order) Allows to produce smoke in use 240 second smoke tablet (Special order) Allows to produce smoke in use 300 second smoke tablet (Special order) Allows to produce smoke in use Smoke Cartridges features Cartridges made of environmentally friendly plastic. Moisture-sealed smoke pellets. Reinforced base for minimal heat transfer. There are only smoke pellets made of high-content chemicals. It is guaranteed for 3 years from the date of delivery. Contains no zinc, rubber powder or mothballs. More than 250 security tests have been carried out. There is a warranty mark on the bottom. Comes in a consumer pack or large pack. Fume Tablet Usage Areas Energy Saving insulation test Ventilation Channel Test Draft Test Leak detection Security tests Negative Pressure Chambers Positive Pressure Rooms Fume Hoods Exhaust fans Stage and Screen Effects Photo Effects Air Balancing test Filtration Test Dust Removal Systems Fire and Smoke Alarm Test Poultry and Livestock Education Heat Exchangers Tanks and Piping Kitchen Hoods Electronic Air Filters Asbestos Reduction Radon Reduction Mechanical system risk management. Waste Treatment Systems

  • Beam dedektör Nedir ? | Platin Teknoloji

    Laser Fire Detection Beam Detectors Optical Beam Smoke Detector is used to provide "wide area" smoke detection. These are generally practical. Traditional point type detector is used in environments where installation and operation is difficult. (installation, wiring and maintenance) It also provides wide coverage at low cost. Optical Beam Smoke Detectors are ideal for high ceilings, dusty and dirty environments, or you may encounter extremely hot environments. Typical applications: - Conference and Exhibition Centers - Shopping malls - Historical buildings - Mosques - Museums - High Ceiling areas - Production Facilities - Warehouses - Airports - Hotels and Casinos - Sports and Entertainment Centers Beam Smoke Detector Types: Optical Beam Smoke Detector works on the principle of darkening of light. Optical Beam Smoke Detector photosensitive element sees light produced by the Transmitter in normal condition. The receiver is calibrated to a preset sensitivity level based on the percentage of total blackening. There are two general types of Beam Optical Smoke Detector - Projected and Reflective. The type used will be dictated by the installation and environmental conditions and restrictions. Projected Beam Smoke Detectors: The transmitter (TX) and receiver (RX) area must be protected up to 100 meters separately installed at each end. The Receiver Control Unit is electrically connected to a second entity installed at ground level. Projected Optical Beam Smoke Detectors are less sensitive to leak reflection as the reflections go back to the Transmitter. As a result, the Projected Optical Smoke Detector Beam can operate within narrow gaps left in the operating environment. In addition, Projected Optical Smoke Detector Beam Emitter and Receiver units are often considered into compact and easy "aesthetic" architectural designs. Reflective Beam Smoke Detectors: Transmitter (TX) and Receiver (RX) are contained in one unit. Up to 100Metres away from the transmitted infrared ray reflected by the back reflector (prism), it is mounted across the unit. The receiver is connected to a control unit that can be either integrated with the Transceiver or mounted at ground level. Reflected Optical Beam Smoke Detectors use less wiring (power and wiring required only at the end of the Radio) and only require the Transceiver to be aligned. However the Reflected Optical Beam Smoke Detector Beam can be vulnerable to reflective items near the IR beam path. Because the reflector has a wide acceptance angle, it does not need to be correctly aligned at both ends of the projected Optical Smoke Detector Beam. About Fireray FFE Beam Detector Everday EV6100 Beam Dedektör Hakkında GST 9105-E Işın Tipi Beam Dedektörü Hakkında About Vesda Osid Beam Detector TNA TX7130 Tanda Beam Dedektör Hakkında

  • Disabled Sound and light guidance price | Platinum Technology

    What is Disabled Sound and Light Emergency Exit Guidance? In service buildings open to public use and in all social and cultural areas, when an emergency occurs such as fire, flood, earthquake, etc. , alarm sirens, flashers, horns and warning loudspeakers placed in various parts of the building work simultaneously in as wide an area as possible to warn people against a sudden danger. . There are exit signs and exit signs used to direct the users inside the building to the emergency exit. However, in a smoke-filled environment, emergency signs created by visual guidance may be less pronounced or completely ineffective. Building occupants may not be familiar with the building and associated emergency exit routes, but they can still access emergency exits somehow with directions and signs. ​ ​ So how will people in panic and shock, hearing and visually impaired individuals reach the emergency exit doors without help !! For visually impaired people to evacuate the building quickly without additional support during the evacuation processes of buildings, conventional emergency direction luminaires and signs will not be sufficient and they will experience serious difficulties. Are there any signs? Solutions that will answer the question should be applied. ​ ​ Disabled audible light guiding luminaires are new generation emergency exit evacuation routing solutions. In short, you can define it as a sound exit armature. The human ear can hear sound signals in the range between 20 Hz and 20000 Hz. The human brain provides time differences between the ears with the difference in sound intensity between the ears. Due to the development of directional sound technology, many studies and researches are carried out to compare the escape times of users from the building with the help of directional sound makers with the escape times made with classical visual signals and signs. These studies have generated a large body of data, with research showing that the use of guided sounders has consistently shown a significant reduction in escape times. Experiments were carried out to confirm this information. Wideband tested at different frequency bandwidths. In addition, pure tone signals were also tested as a reference. The tested sound level is fixed at 75 dB. NFPA's Fire Code [11] Annex-A has shown what ambient sound levels can be for different applications. Fire alarm siren sounds should be higher than ambient sound level. The sound of the fire alarm siren, the voice alarm speaker must be at least 15 dB higher than the ambient sound level . In addition, the sound of the directional disabled emergency audible and light directional luminaire should be at least 15 dB lower than the fire alarm, taking into account the comparability between the two sounds. For this reason, two ambient sound levels were taken into account in the tests; For the accuracy of the aforementioned statements, experts have conducted experiments. One below 60 dB, the other 75 dB. In the test, 36 loudspeakers were placed in a 3 meter diameter circle around the subjects. The circle is marked from 0° to 360° and each sound box is placed at the specified degree. Before starting the test, the subject needs to know: 1) Does not move his head during the test, 2) Different sounds will be played and the subject will be asked to indicate where the sound comes from, 3) Each sound will be played 10 times from a randomly changing sound box each time. 5 seconds between each sound. space will be given and the subject will talk about the place of the voice for 5 seconds. must make a decision in 4) In noise impact tests, a noise sound will be played continuously, during which the subject will distinguish and say the location of the guiding sound signal. For each sound, there are 100 test results. In each test, the direction pointed by the subject has a deviation from the audible sound box, and if the deviation is greater than ±5°, the percentage correct numbers will decrease by one. The results are listed in the analysis. Background noise has some influence on identifying the sound source. Where the background noise level is close to that of the test sound, pure tone (mono-frequency) forms are more difficult to locate, whereas broadband sounds with a larger frequency range are more easily located. ​ ​ When the ambient sound level is below 60 dB, three sounds with bandwidths 0.02-20 kHz, 0.3-16 Khz and 0.5-10 kHz met the above condition. But when the mid sound level was 75 dB, only two sound conditions with bandwidths 0.02-20 kHz, 0.3-16 Khz were provided. Besides, it is easier to pinpoint the exact location of wideband audio; however, the frequency bandwidth should be as wide as possible. The Test concluded accordingly, with test subjects correctly locating the sounder at least 75% of the time, according to the British standard BS PAS 41:2003. The engineering application of directional audio technology faces some problems. Commonly used emergency fire alarm sounds cause confusion for building occupants. Users in buildings may not know what to do when they hear the sound. For this reason, there is a need to clarify escapes in addition to the voice alarm and siren. Users who try to go out into the corridor and steer towards the escape stairs after the siren sound at which the emergency warning is made, will proceed confidently to hear the announcements that they will understand that they can reach the fire stairs for emergency escape when they approach the audible and illuminated emergency exit direction luminaire, when they move in the direction of the sound, and that they are approaching with an increasingly clear sound announcement. This message will enable them to move quickly and safely without the need for visual guidance and evacuation sign systems without having knowledge of the Building. Conventional fire alarm and voice alarm systems both emit an audio signal when an emergency occurs in the building. Disabled emergency exit guidance system with audible light is an additional evacuation aid; however, it is not a system that replaces the above-mentioned fire alarm and voice alarm system. Disabled emergency exit sound and light announcement fixtures should be placed above emergency exit doors and in complex corridor turns. However, emergency audio and light guidance products only on fire escape stairs and emergency exit doors may not provide enough directional sound to reach most of the users. In addition, there may be more than one exit in large, open and large buildings, but the sounds of more than one disabled audible lighted emergency exit routing product may interfere with each other and create confusion. For this reason, detailed project work should be done for disabled emergency sound and light guidance device equipment placement and integrated with the fire scenario. ​ ​ Considering this information It is possible to reach the fire doors and escapes with audible and illuminated announcements from the emergency exit doors. In an emergency, the environment can be noisy due to siren sounds. The emergency voice guidance warning sound should be at least 15 dB lower than the ambient sound level. Despite the ambient noise, it can be heard easily. Orientation can be determined It will make it easier to reach the exit points with the increasing sound level as you get closer. What is Disabled Sound and Light Emergency Exit Guidance? Available How to Integrate a Sound and Light Emergency Exit Guidance System in Buildings ? FOR OUR DISABLED VOICE LIGHT GUIDANCE PRODUCTS

  • Calectro   Havalandırma Kanalı Yangın Algılama  ve Alarm Teknolojisi Türkiye'de | Platin Teknoloji

    Calectro Flood and Moisture Detection Systems Calectro was founded in Gothenburg in 1969 by a young technician, Karl Johan Pettersen. The company was established as an agency company for suppliers in Switzerland and Denmark. Including program electronic thermostats, level controls, time relays etc. The main idea was to find customers with special needs and develop them in close cooperation with the customer. This quickly led to the development of the first electronic overfill protection approved for oil tanks. A completely new electronic freezer protection has also been developed through close contact with a number of control and regulatory companies. In the 1970s and 1980s the company expanded significantly, and in the late 1980s it was expanded to include its own development and production, including Calectro's offering. One-pipe smoke detector for the UG-1 ventilation system, which has become an instant success. Since then, Calectro has offered to develop quality products from accredited suppliers, as well as products developed specifically for its customers. 50 years after its inception, Calectro is a full-fledged technology and distribution company with dealers in many countries and a strong Swedish customer base. Perhaps the best known product is the Uniguard® single-pipe smoke detector, currently used by many project firms in the control and regulation industry in Turkey, Sweden and Europe. Water and Moisture Leak Detection Systems in Platinum Technology; Thanks to this system applied to system rooms, cash registers, storage areas and places affected by water and moisture, the system will activate the siren unit in case of moisture or water formation that may be a risk. According to the pre-prepared scenario, the water discharge engine will activate the heating system and the ventilation system. and if it occurs outside of working hours, it will transmit information by calling the users' phones. Flood detection and alarm system can send mail and sms according to the requests. You can also keep all information in the event memory and report it. With the smart phone application, you can manage the system, report it and receive instant notifications. You can reach Turkey-wide Calectro flood and moisture detection products and special prices for your projects from Platinum Technology. Digital Type Detection Systems - Equipment used - Water detection sensor - Humidity detection sensor - Control Panel - Siren - Telephone search device - Web connection module - SMS module Water Humidity and Leak Detection System Application Areas IT / Server system Rooms Electrical Rooms Heating Cooling centers Data Centers · Hotels Kitchen / Toilet & Vending Areas Hospitals Empty Complexes Supermarkets · Museums Art Galleries Archive Facilities smoke detection in ventilation ducts The purpose of smoke detection in Calectro ventilation ducts is to detect smoke in ventilation systems at an early stage and to send an alarm to the control unit when detected. They can then quickly implement countermeasures such as closing dampers and initiating forced ventilation to limit the spread of smoke. ​ How does single tube smoke detection work in ducts? The system has an air probe (called a venturi tube) integrated control unit cf58d_3194 It is based on bb3b-136bad5cf58d_ (the Uniguard smoke detector is also available with an external control unit). The venturi tube delivers air from the duct to the detector housing installed outside the duct, where a smoke detector detects potential fire particles in the air. In the event of an alarm, the smoke detector sends a signal to the control unit via relays, which then closes the dampers, stops the fans / activates the siren and forwards the alarm to the automation center . The aerodynamic design of the enclosure and tube is crucial to the ability to detect small levels of smoke particles in the air at an early stage Advanced venturi tube technology Uniguard's patented venturi tube is equipped with aerodynamic flanges, the most efficient way to draw air from the depths of the entire ventilation duct and deliver it to the smoke detector. This facilitates the detection of flue gases even at small doses and low air velocities. The effect of the venturi tube has been measured and documented by external laboratories. Flow-optimized enclosure Uniguard's patented enclosure series (UG-3/4/5) has been specially designed using simulation software to achieve maximum flue gas concentration around the smoke detector. In combination with the venturi tube, the enclosures create unmatched sensing performance even at low air volumes. It also has an indicator for easy inspection of the airflow. Automatic sensitivity adjustment Uniguard's smoke detectors have a built-in, automatic sensitivity adjustment that measures the baseline value in airflow each day and compensates for possible changes in the system over time. This minimizes the risk of unwanted alarms and unnecessary maintenance. Led Status Indicator The Uniguard UG-3 version has both an alarm indicator on the smoke detector and LEDs on the back to make it easy to check the alarm status in confined spaces.

  • Mağazacılık ve Perakende | Platin Teknoloji

    Special Solutions for Merchandising and Retail Sector Customer Satisfaction Measurement You have opened a store in the most prestigious point of the shopping mall, you have made architectural applications that are unimaginable to be used by competitors in the store, you sell the best quality products at the most competitive prices, you have trained your staff very well. So how do these affect the customer? People Counting Systems Has there been fewer visitors, or has there been a decrease in the number of customers with no noticeable change in the number of visitors? Here is the answer to this critical question, Customer Welcome Announcement You can automatically greet your customers and visitors who enter your store with a voice announcement, welcome them and remind them of the in-store rules. . Pay attention to social distance, Request the products from the officer. . Face Recognition and Equivalent Detection Software Facial features are defined as very important distinguishing features that individuals have innate, such as fingerprints, that make them different and unique from other people. We offer an effective analysis solution through the camera Store Density Management To prevent sudden and uncontrolled densities in stores, shopping malls and event areas, by following the capacity and making an audible warning when the intensity level increases. We offer counting and announcement solutions that automatically close the entrance doors when they reach the maximum occupancy level. Image and Event Analysis Software It is not possible to view the cameras with the human eye and to interpret the images. Due to all these needs, image - event analysis software has been developed that interprets the images taken from Platin Technology cameras and enables the scenarios determined beforehand. Our experts offer special solutions to minimize the security and operational security risks specific to the retail sector such as chain stores, street stores, markets, restaurants, cafes, street entertainment areas, exhibition areas, discount tents, shopping centers, game parks. CLOSED CIRCUIT CAMERA SYSTEMS: Camera systems, which are used to minimize security and operational risks in accordance with special needs of the retail sector, produce indispensable solutions for business security. We offer i camera solutions and DVR recording device and command control center solutions suitable for all kinds of business and manufacturing conditions. Our products do not only register. It produces alarm scenario solutions in order to prevent the occurrence of events, problems and risks by performing event analysis. All systems record in the structure and quality determined by the institution and provide access to images of appropriate quality when necessary. HUMAN COUNTING AND REPORTING SOLUTIONS: We provide solutions that enable counting of customers and analysis of their movements within the store by analyzing with special software on the camera, where the necessary information is created for the tracking of store circulation and the planning of store-specific operations. KEY MANAGEMENT SYSTEMS: It is ensured that the keys of the store are stored securely and the keys can be easily accessed when necessary, and key management solutions are prevented and securely protected with key management solutions. FIRE DETECTION AND WARNING SYSTEM: Control against fire risk with the fire detection system to be installed in all areas of the store.It provides instant detection of the first occurrence of the fire in the form of particles and allows the fire to be intervened before it grows. For this purpose, the fire alarm systems installed by Platin Teknoloji primarily prevent the personnel in the environment from being in life-threatening danger and material damage to the building. The system has a fire control panel. It evaluates the warnings coming from various type detection elements suitable for the needs of your business and activates the sirens, flashers, telephone dialer. It delivers detailed information to the relevant manager and security personnel. While all these events are taking place, it is ensured that the alarm scenarios previously prepared are activated by sending information to other systems from the moment the fire is detected. ELECTRIC PANELS AUTOMATIC FIRE EXTINGUISHING: Cabinet type extinguishing systems that provide low initial investment and operating costs and high performance are used for electrical panels and cabinets where risks are concentrated. It provides effective extinguishing with HFC227ea and HFC125 etc. extinguishing gases used in fire extinguishers. They are odorless, colorless, non-residual gases that do not harm electrical equipment. WATER MOISTURE DETECTION AND ALARM SYSTEMS: They are the solutions to prevent damage to the establishment as a result of leakage and humidity that will occur out of control from the risky areas such as warehouses, to detect possible raids, to warn the relevant people and to activate the water discharge engine, heating system, ventilation system in accordance with the scenario prepared. AUTOMATIC FIRE EXTINGUISHING SYSTEMS: Solutions are offered to extinguish electrical fires in a very short time for areas with special risks such as in-store system rooms, Automatic extinguishing systems to prevent damage to the business and manufacturing processes. The relevant extinguishing gas / chemical is selected and designed, taking into account the special situation of the establishment and the area where it will be established. The system user will make independent fire detection and initiate the extinguishing process. CABLE TRAYS, VENTILATION SYSTEMS FIRE DETECTION AND DETECTION SYSTEMS: With a special sensor cable to be installed in high risk and difficult to detect areas such as electrical installations and ventilation ducts, sudden temperature changes are detected at the points where it is located and fire is detected before it occurs. Linear Heat Detection is a versatile and economical fire detection product. Considering the initial investment, maintenance, operating costs and operating performance, .Extrem offers economical and performance solutions for fire detection needs. ACCESS CONTROL SYSTEMS: We offer solutions for controlling and reporting the circulation in the store, especially in the areas offered to the use of personnel. The doors of risky rooms are controlled with the access control system due to the determined business, security and occupational safety needs. Control application covers all specified areas. It is possible to report all movements and to make the necessary controls online. The buildings belonging to the enterprise can be controlled and monitored from the same central software wherever they are in the world. FIRE DETECTION AND ALARM SYSTEM TEST EQUIPMENTS: Testing and regular maintenance of systems installed with fire detection equipment is one of the overlooked needs in our country. Platin Technology has offered suitable test gases, cleaning and control apparatus for all detector types such as smoke, heat, gas and carbon monoxide, which make up the fire detection system, to the use of professional operating and fire system maintenance companies. LIVING SOLUTIONS WITHOUT BARRIERS: These are electronic solutions offered for disabled visitors and employees to meet their daily needs risk-free and comfortably within your business and to minimize possible risks. What are the risks? We offer solutions to the need for help and urgent struggle in wet areas, the need for medical assistance in general areas, and the risks of reaching exits without assistance in emergency evacuation processes. EMERGENCY ANNOUNCEMENT AND SOUNDING SYSTEM: Emergency announcement and voice-over systems installed in the store are the solutions used to quickly evacuate customers and personnel in possible emergencies that will provide the necessary ambience by broadcasting in-store music in daily life. Our experts offer solutions to minimize risks specific to the retail industry. Please contact us for special solutions for your projects in Turkey and all countries in our service area.

  • NOVEC 1230 Gas Automatic Extinguishing Systems | Platinum Technology

    NOVEC 1230 Gas Automatic Extinguishing Systems With the actions of the world's governments to regulate possible damages to the ozone layer that will reduce global warming, corporate initiatives are accelerating a transition that will leave environmentally harmful HFC fire extinguisher clean materials such as FM-200® (HFC-227ea) to more sustainable alternatives. Novec 1230 has very low GWP, is not ozone depleting, does not circulate in the atmosphere, so it is not subject to regulatory restrictions or reductions. With FM 200, HFC227, etc.Novec 1230, which is used as an alternative to automatic fire extinguishing systems using gas, can be used safely and with less damage to the environment in automatic fire detection solutions of all risky areas. System Design and Operation: For the volume to be protected with NOVEC 1230 gas, the required gas amount is calculated according to NFPA 12 and ISO 14520 standards and rules, NOVEC 1230 tube is selected according to the gas amount, NOVEC 1230 discharge nozzles are placed at the required points in the room installed with a cross zone fire detection system, With the activation of the smoke detectors, current is sent from the panel to the solenoid valve of the NOVEC 1230 system, The entire NOVEC 1230 is discharged in gaseous state to the protected volume within a maximum of 10 seconds. System operation can be done automatically or manually. Examples of Wide Usage Areas IT / Server Rooms Electrical Rooms Data Centers Safes · Museums Art Galleries Archive Facilities

  • İşitme Engelli için Sesli ve Işıklı Flaşör  Acil Uyarı  Sistemi | Platin Teknoloji

    Audible, Illuminated Emergency Warning System The use of sound and light sirens to warn individuals with no disabilities and especially hearing / hearing impaired individuals in emergency situations is described in accessible project implementations and fire regulations. Sirens and Flashers have been developed with many years of experience and a series of R&D studies for the necessary signaling in order to provide the necessary warnings in case of emergency evacuation and fire detection. It is an effective and accessible evacuation solution for the hearing impaired individuals by turning the sirens of the fire system, which is active in situations requiring emergency evacuation, such as fire, water - flood, earthquake, terrorist incidents, etc. The new generation audible light siren and alerts produce pulse type sound specially produced for fire detection systems. Fire signs and siren signs emit pulsating light, complying with a new European standard EN54-23 for high brightness visual alarm devices. Using light, Sonos Pulse marks reach those who are audiably perishable, or workers in noisy environments, to provide effective evacuation. Patented Pulse Alert Technology distributes light evenly, providing maximum coverage with less consumption. Sonos Impact devices are designed to fulfill evacuation requirements in most rooms with just one device to reduce costs and increase energy efficiency. Sonos Impact devices are a simple process in most environments, with upgrading existing systems to new EN54-23 compliant versions using the same base connections to previous models Pulse Alert Technology; Pulse Alert Technology is a new beacon alert system that produces a light output that can protect most rooms with just one device. Ensuring the most efficient distribution of light, distributing light evenly in order to maximize the effectiveness of new optical systems. The new LED lighting technology is derived in automotive applications, with a Pedigree proven for reliability and performance in the harshest environments. The patented electronic design maximizes electrical efficiency, reducing current consumption to minimize the cost of ownership and allowing more devices to be installed in a single alarm system. Impact Alert Technology EN54-23 compliant system while doing this, design challenges bring all the answers, bring benefits. The flash intensity and frequency of combined devices that warn with light with additional flashes to the siren are described in EN 54 in a way that they do not affect patients who are sensitive to light. If the building is used for housing, hotel, etc. purposes, additional measures should be taken for individuals with hearing impairment. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

  • c-tec | Platin Teknoloji

    C-TEC Founded in 1981, C-TEC is a leading company in the field of quality life safety electronic equipment with its portfolio, which includes traditional and addressable fire alarm systems, power supplies, automatic extinguishing systems, shelter systems for the disabled, call systems and hearing system designs. . If you are looking for quality life safety equipment, you have a solution with C-TEC. Platin Teknoloji sells the c-tec brand's EN 54 approved power supplies for use in fire detection systems. The power supply, which is required by fire regulations in many countries, must comply with EN54-4. C-TEC's VdS approved switched power supplies are among the first products to enter our country's market and are fully compliant with EN54-4. Certified power supplies make it ideal for control of beam / beam detectors, Air sampling systems, External sirens, Electromagnetic door holders, Ventilation systems and the like. More. The product range includes 1.5A, 3A and 5A 24V units and 2A 12V units. For non-mandatory fire and other life safety applications, a wide range of non-EN54 certified 12V and 24V power supplies are also available. Together, the two product ranges provide C-TEC's power supply with the most comprehensive solutions in the industry. CFP702-4 / LPC 2 Zone Conventional Fire Alarm Control Panel CFP704-4 / LPC 4 Zone Conventional Fire Alarm Control Panel CFP708-4 / LPC8 Zoned Conventional Fire Alarm Control Panel EP2033 Zoned Automatic Extinguishing Control Panel - LPCB EN12094-1 Certified Relay Card for EP212EP203 EP210F LCD Display Remote Monitoring and Control Unit, Manual / Automatic Mode Selector, Manual Discharge Button, Suitable For Flush Mounting EP210S Remote Monitoring and Control Unit with LCD Display, Manual / Automatic Mode Selector, Manual Discharge Button, Suitable for Surface Mounting BF359 / 1 Outdoor Type Metal Housing, IP66 EP211 Remote Monitoring and Control Unit - Manual / Automatic Mode Selector EP214 Extinguishing Output Circuit Termination Unit for EP203 (maximum 2 can be used with one EP203, one EP214 comes with EP203) C-Tec EN54 certified Power Supplies BF362-1 EN54-4 Certified Auxiliary Supply and Battery Charger - 24V / 1.5A DC - Space for 2x17Ah BF362-3 EN54-4 Approved Auxiliary Power Supply, 24V / 3A - space for 2x12Ah battery BF362-5 EN54-4 Approved Auxiliary Power Supply, space for 24V / 5A - 2x18Ah battery BF360-12 EN54-4 Certified Auxiliary Supply and Battery Charger - 12V / 2A DC - Space for 1x7Ah battery

  • Panik Buton Acil Yardım İstasyonu | Platin Teknoloji

    Panic Button Emergency Assistance System Panik Buton Acil Durum Yardım Sistemi: Görüntü Panic alarm, emergency medical response button and communication systems are installed in industrial facilities to quickly transmit information to security and health units in possible emergencies. Established panic alarm buttons are implemented in accordance with the existing infrastructure without requiring any modifications. The security risks of individuals and especially children living in metropolitan cities are increasing day by day. Due to the increasing risks, children are the most affected by the increasingly decreasing life comfort. Unfortunately, the right to have childish fun in playgrounds, sports and walking areas, picnic areas is not possible due to risks. We are developing projects in our country to ensure the safety of citizens of all ages. We are positioning additional emergency buttons to the camera system in running tracks, urban forests, playgrounds, children's playgrounds. With this application, you can reach the security guard 24/7 by pressing the panic button and ask for help. While the security guard who has reached the call talks with the person requesting help by voice and video, on the other hand, he can observe the surroundings with the cameras in the environment. can analyze the risk in detail. It can activate sound and light alerts positioned in the field to drive away the suspect. With these applications that we have developed with public institutions and especially municipalities, a safer area is created by ensuring that children have fun and play games in the parks in a safer manner. With the security center that can be accessed directly with the panic button, needs such as health assistance, police, police, fire brigade, etc. can be controlled from a single center. Quick intervention in health risks such as falls, fainting, etc. Quick intervention in child abduction and disappearance risks Quick response to the risks of substance addicts Prevention of all kinds of abuse, harassment, etc. Batting, fighting and preventing all kinds of incidents Prevention of theft, snatching and extortion The emergency phone can be easily integrated into an environment with the existing telephony infrastructure. Any analog exchange can be connected to the GSM network powerhouse or directly to a landline (PSTN). For example, to control the door lock, while the extra switch that comes with a single integrated intercom can also be added to control other devices. The integrated amplifier comes standard as well as a tamper switch connection option on the current security exchange. Simple programming is provided that will guide you through adjusting parameters directly from your phone, without the need to use a voice menu site or a PC. For All Panic Alarm Button Alternatives Panik Buton Acil Durum Yardım Sistemi: Product

  • Güvenlik Otomasyon ve Entegrasyon Yazılımları | Platin Teknoloji

    Security Automation and Integration Software CCTV system, Fire detection and notification system, Security automation, Building management, Access Control system and all weak current systems central rooftop software solutions that provide integration. The CCTV system is a closed circuit camera system to be installed for event monitoring in the facility. The entire system consists of IP based devices. We provide CCTV System, card access system and fire detection, security automation, building management system and software based fully integrated. In this way, it can be provided to work integrated with the scenario between systems. Example: Fire scenario: Possible alarms in the fire detection system, how will other systems work? The camera system shows the detected floor. Access control system opens doors for rapid evacuation. The building automation system starts the evacuation scenario for the control of smoke. The elevator system comes to the ground floor and is allocated to the fire brigade use. The security system activates the sensors in risky areas. Turnstiles allow free passage in the exit direction for rapid evacuation. Sample Security scenario: By making the image visible on the operator screen with audible warning in the fire alarm information formed at the point where the camera is located, operations can be carried out quickly and safely. In the access control system, the operation can be accelerated by making the relevant point of the camera in the area prominent on the operator's screen with an audible warning. In security automation, making the camera facing the area of ​​the door open for a long time visible on the operator's screen, and automatically forwarding the event to the relevant managers by mail. Integration can be made for many events with scenarios specific to the structure and risks of the building.

  • IP Tabanlı Kart Okuyucu ile Geçiş Kontrol Çözümleri | Platin Teknoloji

    Wireless Access Control and Electric Lock Striker You want to apply access control to your existing various doors. In the table that appears, the route of carrying the cables up to the door and the need to make modifications in return for the door lock or door has emerged and you had to review or cancel the decision of the access control application for your business due to this table! The solution is aperio, produced for wireless access control application, where reader and lock are together. With the change of the door handle and lock mechanism, it will be an integrated access control application with your existing system and cards. Suitable for application in various door types in a wide range of products. Aperio is internationally certified, with its high security and long battery life. The wireless nature of the system allows the addition of new controlled doors by lowering the installation costs. Easily integrates into existing systems Electronic cylinder application puts an end to the problem of carrying keys. Can be assembled in less than 2 minutes Reduces installation costs by 60% Can be used for 3 years without changing the battery

  • klaxon siren flaşör | Platin Teknoloji

    Klaxon Siren Flasher Equipment It is a famous specialist brand in the UK and worldwide in the design and production of first class siren & beacon equipment. Thanks to innovation and technical expertise, Klaxon Signals manufactures audio and visual signaling equipment used in fire evacuation, industrial signaling and mass notification markets worldwide. Millions of people are protected and informed every day by Klaxon Signal products. Klaxon Signal's wide product range includes: electronic sirens; sound enhanced sirens; sirens; signs and wide area notification equipment. Design philosophy: Every Klaxon product starts with the same simple design philosophy to better realize all other products in its class. Focusing on performance, simplicity, style and reliability, the product requirements are designed according to advanced designs that provide high quality signaling solutions. UK Made for Total Control: With the design and manufacture of all products in the most advanced UK facilities, full control is ensured for all aspects of development. Klaxon Signal's lean-based demand-based operations guarantee the highest possible product quality and delivery performance. Customer focused: Offering a multi-award-winning level of service and training, Klaxon Signals offers a standard of customer service and support unmatched in the industry. Quality Policy: Texecom operates with an ISO 9001: 2008 and OHAS1801: 2007 certified Business Management System. This company's Quality Policy is formalized and documented in the Business Management System. Klakson Siren and Flashers have developed with a series of R&D studies and many years of experience for the necessary signaling in order to provide the necessary warnings in case of emergency evacuation and fire detection. Sonos manufactures pulse-type sound tailored for fire detection systems .. fire signs and siren signs emit pulsating light, complying with the new European standard EN54-23 for high brightness visual alarm devices. Using light, Sonos Pulse marks reach those who are audiably perishable, or workers in noisy environments, to provide effective evacuation. Patented Pulse Alert Technology distributes light evenly, providing maximum coverage with less consumption. Sonos Impact devices are designed to fulfill evacuation requirements in most rooms with just one device to reduce costs and increase energy efficiency. Sonos Impact devices are a simple process in most environments, with upgrading existing systems to new EN54-23 compliant versions using the same base connections to previous models Pulse Warning Technology Pulse Alert Technology is a new beacon alert system that produces a light output that can protect most rooms with just one device. Ensuring the most efficient distribution of light, distributing light evenly in order to maximize the effectiveness of new optical systems. The new LED lighting technology is derived in automotive applications, with a Pedigree proven for reliability and performance in the harshest environments. The patented electronic design maximizes electrical efficiency, reducing current consumption to minimize the cost of ownership and allowing more devices to be installed in a single alarm system. Impact Alert Technology EN54-23 compliant system provides all the benefits it can bring, whilst answering all of the design challenges in doing so. Acoustic Expertise Klakson Sirens are sound propagation experts with each and every signaling product that includes perfectly designed acoustic chambers to enhance sound output performance. The result is a range of evacuation signaling devices that are clear, unmissable and error-free. Further details of the technology behind the market leading range of acoustic signal devices Klakson will be available soon ESF-5003 EXTERNAL SIREN FLASHER Sonos Wall Mount, Deep Base, Red body / flasher, 97dB, IP65, EN54-23 ESF-5004 BUILT-IN SIREN FLASHER Sonos Wall Mount, Thin Base, Red body / flasher, 97dB, IP21, EN54-23 ESF-5007 EXTERNAL SIREN FLASHER Sonos Ceiling Mount, Deep Base, Red body / flasher, 97dB, IP65, EN54-23 ESF-5008 BUILT-IN SIREN FLASHER Sonos Ceiling Mount, Thin Base, Red body / flasher, 97dB, IP21, EN54-23 PSC-0042 EXTERNAL SIREN LED FLASHER Sonos Deep Base, Red body / lens, 32 Voices, 106Db, IP65. EN54-3 PSC-0047 Internal SIREN LED FLASHER Sonos Slim Base, Red body / lens, 32 Voices, 106dB, IP21, EN54-3 PSS-0003 INTERNAL SIREN Sonos Thin Base, Red body, 32 voices, 106dB, IP21, EN54-3 KLAXON SIREN -FLASHER WARNING LIGHTS PRODUCTS AND CODES PNC-0001NEXUS 105 DC SOUNDER - XENON BEACON RED PNC-0002NEXUS 105 DC SOUNDER - XENON BEACON AMBER PNC-0020NEXUS 105 DC SND BCN CLEAR 5J XENON BEACON PNC-0041NEXUS 105 DC SOUNDER - GREEN 5J XENON BEACON PNC-0043NEXUS 105 DC SOUNDER - BLUE 5J XENON BEACON PNC-0005NEXUS 105 AC SOUNDER - XENON BEACON RED PNC-0007NEXUS 105 AC SOUNDER - XENON BEACON AMBER PNC-0019NEXUS 105 AC SOUNDER - XENON BEACON CLEAR PNC-0042NEXUS 105 AC SOUNDER - GREEN 5J XENON BEACON PNC-0044NEXUS 105 AC SOUNDER - BLUE 5J XENON BEACON PNC-0013NEXUS 110 DC SOUNDER - RED 5J XENON BEACON PNC-0015NEXUS 110 DC SOUNDER - AMBER 5J XENON BEACON PNC-0021NEXUS 110 DC SOUNDER - CLEAR 5J XENON BEACON PNC-0048NEXUS 110 DC SOUNDER - GREEN 5J XENON BEACON PNC-0050NEXUS 110 DC SOUNDER - BLUE 5J XENON BEACON PNC-0016NEXUS 110 AC SOUNDER - RED 5J XENON BEACON PNC-0018NEXUS 110 AC SOUNDER - AMBER 5J XENON BEACON PNC-0049NEXUS 110 AC SOUNDER - GREEN 5J XENON BEACON PNC-0051NEXUS 110 AC SOUNDER - BLUE 5J XENON BEACON PNC-0072NEXUS 110 AC SOUNDER - CLEAR 5J XENON BEACON PNC-0003NEXUS 120 DC SOUNDER - XENON BEACON RED PNC-0004NEXUS 120 DC SOUNDER - XENON BEACON AMBER PNC-0022NEXUS 120 DC SND BCN CLEAR 5J XENON BEACON PNC-0055NEXUS 120 DC SOUNDER - GREEN 5J XENON BEACON PNC-0057NEXUS 120 DC SOUNDER - BLUE 5J XENON BEACON PNC-0009NEXUS 120 AC SOUNDER - RED 5J XENON BEACON PNC-0011NEXUS 120 AC SOUNDER - XENON BEACON AMBER PNC-0023NEXUS 120 AC SND Xenon Beacon Clear PNC-0056NEXUS 120 AC SOUNDER - GREEN 5J XENON BEACON PNC-0058NEXUS 120 AC SOUNDER - BLUE 5J XENON BEACON PNC-0024NEXUS 105 DC SOUNDER - RED LED BEACON PNC-0028NEXUS 105 DC SOUNDER - AMBER LED BEACON PNC-0045NEXUS 105 DC SOUNDER - CLEAR (WHITE) LED BEACON PNC-0046NEXUS 105 DC SOUNDER - GREEN LED BEACON PNC-0047NEXUS 105 DC SOUNDER - BLUE LED BEACON PNC-0029NEXUS 110 DC SOUNDER - RED LED BEACON PNC-0034NEXUS 110 DC SOUNDER - AMBER LED BEACON PNC-0052NEXUS 110 DC SOUNDER - CLEAR (WHITE) LED BEACON PNC-0053NEXUS 110 DC SOUNDER - GREEN LED BEACON PNC-0054NEXUS 110 DC SOUNDER - BLUE LED BEACON PNC-0062NEXUS 110 24/48 AC SOUNDER-RED LED BEACON PNC-0063NEXUS 110 24/48 AC SOUNDER-AMBER LED BEACON PNC-0035NEXUS 120 DC SOUNDER - RED LED BEACON PNC-0039NEXUS 120 DC SOUNDER - AMBER LED BEACON PNC-0059NEXUS 120 DC SOUNDER - CLEAR (WHITE) LED BEACON PNC-0060NEXUS 120 DC SOUNDER - GREEN LED BEACON PNC-0061NEXUS 120 DC SOUNDER - BLUE LED BEACON PNS-0001NEXUS 105 DC SOUNDER ONLY PNS-0009NEXUS 105 AC SOUNDER ONLY PNS-0013NEXUS 110 DC SOUNDER ONLY PNS-0018NEXUS 110 AC SOUNDER ONLY PNS-0020NEXUS 110 24/48 AC SOUNDER PNS-0005NEXUS 120 DC SOUNDER ONLY PNS-0011NEXUS 120 AC SOUNDER ONLY PNV-0001NEXUS 110 VOICE SOUNDER 24V DC PNV-0016NEXUS 110 VOICE SOUNDER 110/230V AC PNV-0030NEXUS 110 VOICE SOUNDER CLEAR XENON BEACON 110/230V AC PNV-0003NEXUS 110 VOICE SOUNDER-RED LED BEACON 24V DC GAS EXTINGUISH PNV-0006NEXUS 110 VOICE SOUNDER RED LED BEACON 24V DC PNV-0007NEXUS 110 VOICE SOUNDER AMBER LED BEACON 24V DC PNV-0008NEXUS 110 VOICE SOUNDER GREEN LED BEACON 24V DC PNV-0009NEXUS 110 VOICE SOUNDER BLUE LED BEACON 24V DC PNV-0010NEXUS 110 VOICE SOUNDER CLEAR LED BEACON 24V DC PNV-0011NEXUS 110 VOICE SOUNDER RED XENON BEACON 24V DC PNV-0012NEXUS 110 VOICE SOUNDER AMBER XENON BEACON 24V DC PNV-0013NEXUS 110 VOICE SOUNDER GREEN XENON BEACON 24V DC PNV-0014NEXUS 110 VOICE SOUNDER BLUE XENON BEACON 24V DC PNV-0015NEXUS 110 VOICE SOUNDER CLEAR XENON BEACON 24V DC PNV-0018NEXUS 110 VOICE SOUNDER RED XENON BEACON 110/230V AC PNV-0019NEXUS 110 VOICE SOUNDER AMBER XENON BEACON 110/230V AC PNV-0020NEXUS 110 VOICE SOUNDER GREEN XENON BEACON 110/230V AC PNV-0021NEXUS 110 VOICE SOUNDER BLUE XENON BEACON 110/230V AC PNV-0004VOICE MESSAGE INTERFACE UNIT-GAS EXTINGUISHING SYSTEMS PNV-0005VOICE MESSAGE INTERFACE UNIT - INDUSTRIAL SYSTEMS PNV-0022FIRE SYSTEM INTERFACE UNIT VOICE PSB-0060SONOS BCN 10-60V DC 5J XEN AMB/RED SB PSB-0061SONOS BCN 10-60V DC 5J XEN RED/RED SB PSB-0065SONOS 2J XENON BCN 10-60V DC RED LENS/RED SB PSB-0068SONOS 2J XENON BCN 10-60V DC CLEAR LENS/RED SB PSB-0090Sonos 2J Xenon Beacon amber lens PSB-0107SONOS 2J XENON BCN 10-60V DC BLUE LENS/RED SB PSB-0109SONOS 2J XENON BCN 10-60V DC GREEN LENS/RED SB PSB-0039SONOS BCN 10-60V DC RED/RED 5J XEN DB PSB-0040SONOS BCN 10-60V DC AMB/RED 5J XEN DB PSB-0041SONOS BCN 10-60V DC CLR/RED 5J XEN DB PSB-0055SONOS BCN 10-60V DC GRE/RED 5J XEN DB PSB-0057SONOS BCN 10-60V DC 5J XEN BLUE/RED DB PSB-0058SONOS BCN 10-60V DC CLR/RED 5J XEN WHITE DB PSB-0059SONOS BCN 10-60V DC 5J XEN AMB/WHI DB PSB-0062SONOS 2J XENON BCN 10-60V DC RED LENS/RED DB PSB-0063SONOS 2J XENON BCN 10-60V DC BLUE LENS/RED DB PSB-0064SONOS 2J XENON BCN 10-60V DC AMBER LENS/RED DB PSB-0091Sonos 2J Xenon Beacon clear lens PSB-0108SONOS 2J XENON BCN 10-60V DC GREEN LENS/RED DB PSB-0116SONOS BCN 10-60V DC RED/RED 5J XEN WHITE DB PSB-0117SONOS BCN 10-60V DC 5J XEN BLUE/WHI DB PSB-0118SONOS BCN 10-60V DC GRE/RED 5J XEN WHITE DB PSB-0002Sonos Beacon 110/230V AC Red/Red Deep Base PSB-0004SONOS BCN 110/230V AC AMB/RED DB PSB-0034SONOS BEACON AM/WHI DEEP BASE 110/230 VAC PSB-0038SONOS BCN 110/230V AC CLE/RED DB PSB-0054SONOS 5J XENON BCN 110/230V AC GREEN/RED DB PSB-0056SONOS XENON BCN 110/230V AC 5J BLUE/RED DB PSB-0009SONOS RED/RED LED 17-60V DC STS PSB-0026SONOS AMB/RED LED 17-60V DC STS PSB-0042SONOS LED BCN CLE/RED LED 17-60V DC W SB PSB-0047SONOS LED BCN CLR LENS/RED LED 17-60V DC RED SB PSB-0048SONOS RED/WHI LED 17-60V DC STS PSB-0050SONOS LED BCN ONLY 17-60V DC AMB/WHI STS PSB-0017SONOS LED BCN 17-60V DC RED/RED DTS PSB-0031SONOS LED BCN 17-60V DC AMB/RED DTS PSB-0035SONOS LED BCN ONLY 17-60V DC RED/WHI DTS PSB-0036SONOS LED BCN ONLY 17-60V DC AMB/WHI DTS PSB-0045SONOS LED BCN CLR LENS/RED LED 17-60V DC WHI DB PSB-0077SONOS LED BCN 17-60V DC CLEAR/RED DTS PSB-0033SONOS BCN 110/230 RED/WHITE DEEP BASE PSB-0119SONOS BCN 110/230V AC CLEAR/WHITE DEEP BASE PSB-0120SONOS BCN 110/230V AC BLUE/WHITE DEEP BASE PSB-0121SONOS BCN 110/230V AC GREEN/WHITE DEEP BASE PSC-0002SONOS RED/RED SND/LED 17-60V DC STS PSC-0025SONOS AMB/RED SND/LED 8-60V DC STS PSC-0035SONOS SND/LED BCN 17-60V DC RED/WHI STS PSC-0040SONOS SND/LED BCN 17-60V DC AMB/WHI STS PSC-0047SONOS SND/LED BCN 17-60V DC RED/RED STB C/O PSC-0050SONOS SOUNDER/LED BCN AMB/RED DC SHALLOW BASE C/O PSC-0052SONOS SND/LED BCN CLEAR LENS/RED LED WHITE STS PSC-0013SONOS SND/LED BCN 17-60V DC RED/RED DTS PSC-0027SONOS SND/LED BCN 17-60V DC AMB/RED DTS PSC-0029SONOS SND/LED BCN 17-60V DC RED/WHI DTS PSC-0034SONOS DC AMB LENS/WHITE DEEP BASE SOUNDER/LED BCN PSC-0042SONOS SND/LED BCN 17-60v DC RED/RED DTS C/O PSC-0049SONOS SND/LED BCN 17-60V DC AMB/RED DTS C/O PSC-0053SONOS SND/LED BCN 17-60V DC CLR LEN/RED LED WHI DB PSC-0059SONOS SND/LED BCN 17-60V DC CLR LEN/RED LED WHI DTS C/O PSC-0060SONOS SND BCN 110/230V AC AMB/WHI DB PSS-0094SONOS SND BCN 110/230V AC RED/RED DB PSS-0096SONOS SND BCN 110/230V AC AMB/RED DB PSS-0003SONOS RED/RED SND 9-60V DC SB/TS PSS-0039SONOS WHI/WHI SND 9-60V DC SB/TS PSS-0020SONOS SND 9-60V DC RED/RED DTS PSS-0050SONOS SND 9-60V DC WHI/WHI DTS PSS-0033COMPACT (BEDHEAD) SOUNDER RED PSS-0035COMPACT (BEDHEAD) SOUNDER WHITE PSS-0060SONOS SND 110/230V AC RED DB PSS-0063SONOS SND 110/230V AC WHI/WHI DB PSV-0009SONOS VOICE SOUNDER MULTI M 24V DC RED DEEP BASE PSV-0010SONOS VOICE SOUNDER MULTI M 24V DC RED SHALLOW BASE PSV-0011SONOS VOICE SOUNDER MULTI M 24V DC WHITE DEEP BASE PSV-0012SONOS VOICE SOUNDER MULTI M 24V DC WHITE SHALLOW BASE PSV-0013SONOS VOICE SOUNDER LED BCN MULTI M 24V DC RED DEEP BASE PSV-0014SONOS VOICE SOUNDER LED BCN MULTI M 24V DC RED SHALLOW BASE PSV-0015SONOS VOICE SNDR LED BCN MM 24V DC RED LED CLR LENS WHI DB PSV-0016SONOS VOICE SNDR LED BCN MM 24V DC RED LED CLR LENS WHI SB ENC-6001Nexus Pulse 105 Sounder Beacon White Flash ENC-6002Nexus Pulse 110 Sounder Beacon White Flash END-6001Nexus Pulse 105 Sounder Beacon Red Light END-6002Nexus Pulse 110 Sounder Beacon Red ESB-5007Sonos Pulse Ceiling Beacon DB Red Body White Flash ESB-5005Sonos Pulse Ceiling Beacon DB White Body White Flash ESB-5008Sonos Pulse Ceiling Beacon SB Red Body White Flash ESB-5006Sonos Pulse Ceiling Beacon SB White Body White Flash ESB-5003Sonos Pulse Wall Beacon DB Red Body White Flash ESB-5001Sonos Pulse Wall Beacon DB White Body White Flash ESB-5004Sonos Pulse Wall Beacon SB Red Body White Flash ESB-5002Sonos Pulse Wall Beacon SB White Body White Flash ESC-5001Sonos Pulse Wall Sounder Beacon DB White Body White Flash ESC-5003Sonos Pulse Wall Sndr/Bcn DB Red Body White Flash Class A ESF-5001Sonos Pulse Wall Sndr/Bcn DB White Body Red Flash Class A ESF-5003Sonos Pulse Wall Sndr/Bcn DB Red Body Red Flash Class A ESC-5002Sonos Pulse Wall Sounder Beacon SB White Body White Flash ESC-5004Sonos Pulse Wall Sounder Beacon SB Red Body White Flash ESF-5002Sonos Pulse Wall Sounder Beacon SB White Body Red Flash ESF-5004Sonos Pulse Wall Sounder Beacon SB Red Body Red Flash ESC-5005Sonos Pulse Ceiling Sounder Beacon DB White Body White Flash ESC-5007Sonos Pulse Ceiling Sndr/Bcn DB Red Body White Flash Class A ESF-5005Sonos Pulse Ceiling Sounder Beacon DB White Body Red Flash ESF-5007Sonos Pulse Ceiling Sndr/Bcn DB Red Body Red Flash Class A ESC-5006Sonos Pulse Ceiling Sounder Beacon SB White Body White Flash ESC-5008Sonos Pulse Ceiling Sounder Beacon SB Red Body White Flash ESF-5006Sonos Pulse Ceiling Sounder Beacon SB White Body Red Flash ESF-5008Sonos Pulse Ceiling Sounder Beacon SB Red Body Red Flash ESD-5007Sonos Pulse Ceiling Beacon DB Red Body Red Flash ESD-5005Sonos Pulse Ceiling Beacon DB White Body Red Flash ESD-5008Sonos Pulse Ceiling Beacon SB Red Body Red Flash ESD-5006Sonos Pulse Ceiling Beacon SB White Body Red Flash ESD-5003Sonos Pulse Wall Beacon DB Red Body Red Flash ESD-5001Sonos Pulse Wall Beacon DB White Body Red Flash ESD-5004Sonos Pulse Wall Beacon SB Red Body Red Flash ESD-5002Sonos Pulse Wall Beacon SB White Body Red Flash GBV-0001Odyssey XW 868MHz WDA-0001Odyssey X1 Cover (White/Blue) WDA-0002Odyssey X1 Cover (White/Red) WDA-0003 Odyssey X1 Cover (White/White) WDA-0004Odyssey X1 Cover (Black/Blue) WDA-0005Odyssey X1 Cover (Black/Red) WDA-0006Odyssey X1 Cover (Black/White) WDA-0007Odyssey X1 Cover (White/Green) WDA-0008Odyssey X1 Cover (Black/Green) WDB-0001Odyssey X3 Cover (White/Blue) WDB-0002Odyssey X3 Cover (White/Red) WDB-0003 Odyssey X3 Cover (White/White) WDB-0004Odyssey X3 Cover (Black/Blue) WDB-0005Odyssey X3 Cover (Black/Red) WDB-0006Odyssey X3 Cover (Black/White) WDB-0007Odyssey X3 Cover (Black/Green) WDB-0008Odyssey X3 Cover (White/Green) WDD-0002Odyssey X WDD-0001Odyssey XE WDC-0002Odyssey XB WDC-0001Odyssey X-BE WDE-0001Odyssey X-Dummy

  • Disabled Emergency Exit Guidance System with Audio, Illuminated Announcement | Platinum Technology

    Voice and Light Announcement for the Disabled Emergency Exit Routing Products Our products are designed in the R&D Center registered by the Ministry of Science, Industry and Technology. Domestic Production and Mass production are carried out in the EDS factory. It will help the disabled and non-disabled individuals to reach the fire escape stairs with emergency exit doors created for evacuation from all buildings open to public use without the need for the support and assistance of another person in case of possible fire, earthquake, terrorism, etc., and help them to find escape easily in order to ensure rapid and safe evacuation. Disabled voice and light guidance products. In terms of easy understanding, we can define it as audible exit armature. '' Emergency exit is here '', '' Door is here '', '' Exit is here '' etc. contains short and concise audio descriptions. With the products presented below for your review, we offer integrated solutions to fire detection system scenarios with wired, wireless integration suitable for the technical infrastructure and brand-independent fire detection systems and equipment of existing buildings. Public exposure 77.1 85. 1017 PK_D_E07 SOUND LIGHT EMERGENCY EXIT GUIDANCE SYSTEM It meets the requirements described with the IP ADDRESS pose and more. You can get support from our experts for our solutions. What is Disabled Sound and Light Emergency Exit Guidance? How to Integrate Sound and Light Emergency Exit Guidance System in Existing Buildings? ACA ES 24 DISABLED SOUND LIGHT GUIDANCE Brand-independent integration, Wireless, Wired Connection, Smoke - heat detector supported, In accordance with 77.185.1017 public exposure More information ACA ES 12 DISABLED SOUND LIGHT GUIDANCE Brand-independent integration, Wireless, suitable for Wired Connection More information ACA 40 5GEN DISABLED SOUND LIGHT ROUTING Suitable for brand-independent integration, Wired Connection, Intrusion and Fire detection system integration. Independent cordless operation More information ACA 40 DISABLED SOUND LIGHT GUIDING FIXTURE Suitable for brand-independent integration, Wired Connection, Intrusion and Fire detection system integration. More information ACA 2O DISABLED SOUND LIGHT GUIDING FIXTURE More information ACA ES 24 M DISABLED SOUND LIGHT ROUTING Brand-independent integration, Wireless, Wired Connection, Smoke - heat detector supported, Additional speaker support, external environment In accordance with 77.185.1017 public exposure More information Suitable for brand-independent integration, Wired Connection, Intrusion and Fire detection system integration. ACA ES 24 M DISABLED SOUND LIGHT ROUTING Brand-independent integration, Wireless, Wired Connection, Smoke - heat detector supported, Additional speaker support, external environment In accordance with 77.185.1017 public exposure More information In the R&D Process Before the end of 2022 will be available for sale TCP/IP Based, Dali Integrated, Scenarios can be managed from the central system. Sound and light emergency exit direction and evacuation fixture For Effective Accessibility Practices for the Visually and Hearing Impaired. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS A Promotion Including All of Our Disabled Voice and Illuminated Emergency Exit Routing Products

  • Pilli Sigara Dumanı Dedektörü | Platin Teknoloji

    Cigarette, Tobacco Smoke Detector We offer effective detection with cigarette smoke detector solutions to integrate with building automation, alarm, etc. systems. We offer solutions and alarm detector solutions that detect the smoke of all products that contain tobacco, which are prohibited and harmful to health and pose a risk to use in businesses. The answer to the frequently asked question, "Does the smoke detector make a cigarette?" Although the smoke detector is sensitive to the smoke that creates the fire due to its sensor structure, it will not be able to detect without the formation of the so-called under-smoke environment for tobacco smoke detection. The solution for fast and early cigarette smoke detection is "Anti Tobacco" tobacco smoke detection and alarm detectors. You can minimize your risks with our cigarette smoke detection solutions that help control workforce losses, health and fire risks caused by non-compliance with tobacco use ban in businesses. "Cigarette smoke detection detectors: They are especially sensitive to tobacco and cigarette smoke. Selectable sensitivity level on some models. They are manufactured to meet the needs of different institutions and organizations. Prevention of smoking in prohibited areas beyond your control and detection of cigarette smoke in all areas from theaters to movie theaters, hotels to fairgrounds, from factories to industrial facilities, from textile workshops to chemical areas. It is used to minimize, deter and detect the risks that may occur as a result of uncontrolled smoking, thanks to the audible stimulation of cigarette smoke after detection. Product General Features Easy installation and maintenance Photoelectric detection technology Test function • High sensitivity to tobacco smoke Warning sounds • Can be linked together Optional remote indicator or relay output Guaranteed and high quality products and stable operation Usage areas • Factories • Flammable Flammable material facilities Hotel, hostel and student dormitories WC and changing cabins Textile industry manufacturing and storage areas Advantages • Early and effective cigarette tobacco smoke detection Integration with existing brand-independent alarm systems • Wired and wireless detector options With the two different solutions offered, it can monitor all risks with a central system. You can deter them with wireless solutions. 1. Central system solutions 2. Wireless (Battery powered) solutions Our products are designed to detect tobacco smoke in accordance with its particle structure. It is only possible to detect the smoke that occurs during the use of cigarettes, etc. with cigarette - tobacco detectors manufactured for these purposes. With all other fire and smoke detectors, very dense smoke is required to detect cigarette smoke. You can reach PLATIN TECHNOLOGY experts for special solutions for your business. You can minimize your risks with our cigarette smoke detection solutions that control the workforce losses, health and fire risks caused by non-compliance with the tobacco use ban in businesses. "Cigarette smoke detection detectors: Especially sensitive to tobacco and cigarette smoke. ​ ​ Selectable sensitivity level on some models. They are manufactured to meet the needs of different institutions and organizations. From theaters to movie theaters, from hotels to fairgrounds, from factories to industrial facilities, from textile workshops to chemical areas, preventing smoking and detecting cigarette smoke in prohibited areas beyond your control by your staff and visitors. It is used to minimize, deter and detect the risks that will occur as a result of uncontrolled smoking, thanks to the audible warning after the detection of cigarette smoke. ​ ​ Cigarette Smoke Detector Features • Easy installation and maintenance • Photoelectric sensing technology • Test function • High Tobacco smoke sensitivity • Warning sounds • Interconnectable • Optional remote indicator or relay output • Guaranteed and high quality products and stable operation ​ ​ Cigarette Smoke Detector Usage Areas • Factories • Flammable Flammable Substance Facilities • Hotels, Pensions and student dormitories • WC and changing cabins • Textile industry manufacturing and storage areas Cigarette & Tobacco Smoke Detector Advantages • Early and effective cigarette tobacco smoke detection • Integration with existing brand-independent alarm systems • Wired and wireless detector options ​ ​ With three different solutions offered, it can monitor all risks with a central system. You can make quick and easy installation with wireless solutions. ​ ​ 1. Conventional cigarette smoke detector with control panel 2. Battery powered cigarette smoke detector 3. Relay type cigarette smoke detector ​ ​ Our products are designed to detect tobacco smoke in accordance with its particle structure . It is only possible to detect the smoke that arises from the use of cigarettes, etc., with cigarette-tobacco detectors manufactured for these purposes. With all other fire and smoke detectors, very dense smoke is required to detect cigarette smoke. You can reach PLATIN TECHNOLOGY experts for special solutions for your business. You can reach all our cigarette smoke detection and alarm solutions here.

  • Acil Durum Toplanma Alanı Afet Raporlaması | Platin Teknoloji

    Emergency Meeting Area Disaster Reporting In the emergency action plans included in the occupational health and safety practices, the need for the rapid evacuation of the building in accidents or disasters and the safe gathering of evacuated people in the gathering areas and accessing the information of the insiders has emerged. For detailed information, you can get support from Platin Technology experts. In the emergency action plans, in which OHS occupational health and safety practices are increasingly increasing in our country, the need for the evacuation of the building by swindle in human-induced or natural disasters and the need to keep the evacuated people safely in the gathering areas and to access the information of the insiders quickly emerged. HUMAN-CAUSED DISASTERS Nuclear, biological, chemical accidents Miscellaneous accidents Industrial accidents Irregular area accidents Risks such as theft, Terror etc. NATURAL SOURCE DISASTERS Earthquake Floods, floods Landslides, rock falls, landslides Hail raids Storms, Hurricanes Volcano and Volcano Eruptions Fires AREAS WHERE THE MEETING PLACE APPLICATION IS MADE Industrial facilities Energy facilities Factories, Industrial establishments Public buildings Hotel, Motel, Holiday Village etc. touristic facilities Residential areas Military facilities School University campuses Multi-storey plazas Shopping malls Factories, storage areas Logistics areas, Ports, Station and bus stations Platinum technology experts offer new generation internal location tracking solutions and IOT integration, where you can access the list and detailed information of the people who come to the meeting point in case of emergency with a single click, and provide quick intervention with a single button.

  • Jam CDBi-485 Su baskın Dedektörü | Platin Teknoloji

    Jam Aqua Alarm CDBi-485 Zone Detector Module Field detector module for connection to the detection cable. It is made of stainless and ABS plastic. LED on the module and internal alarm sound to give local alarm indication. For connection to the I-Zone Mini control panel. FEATURES 'Aqualarm' CDBi-485 Zone Detector Module, one purpose ABS Box, housing of the electronic circuit. A locking line socket at one end of the module It is installed to allow the connection of the detection cable. The other end is equipped with cloths For connection to the PCB. There is a red LED at the top of the module. The The red LED will flash to indicate an alarm condition. Alarm status and monitoring Single RS485 connection to the I-Zone Mini control panel. The module comes complete with a End-to-End Resistor Plug; Detection cable. Normal operating voltage: 12 volt dc Quiescent Current: <10mA. Per detector. Alarm Current: <100mA. Per detector. Detector Oscillator frequency: 6kHz Recommended connecting cable: 4 Core Cable 22AWG Screened Twisted Pair Belden Ref 8723 Line voltage drop: 1.5 mV / m. Approvals: BS EN ISO 9001: 1994 EMC Directive 89/336 / EEC CD-X Detect Cable Cable detection for all models of the control panel. Constructed of hard-worn Helegaine 66 nylon extinguishing arms providing greater protection against dust and conductive contamination. Locking plugs and sockets for a secure connection. Available in modular lengths of 1, 2, 5 and 10 meters. For connection to Detector Modules and Placement equipment. FEATURE 'Aqualarm' water leak Detection Cable, two flat tinned copper The braids are separated and protected with Helegaine self-extinguishing nylon 66 sheath. This type of configuration protects the sensing centers against dust, others Conductive contamination types and mechanical damage. Cable available In modular lengths of 1, 2, 5 and 10 / m. Each cable is pre-terminated with a male And female locking line plug and socket. Installation Method When a liquid leaking from the piping needs to be protected, the Detection Cable It should be fixed with cable ties under the pipeline, then steam Gasket or thermal protection installed or fixed in the floorboard Just below the pipeline, using appropriate clips or ties. Where protection is required from a liquid leaking from equipment, e.g. water-cooled Computers, chiller factory, air conditioning units etc. Detection Cable for It is fixed on the floor around the equipment. Cable Voltage: No greater than 2 volts from DC Cable diameter: 8 mm Maximum Detection Cable length: Reconstruction System: 50 / m (including bridge cable). ZLM-500: 500 / m (including leader / jumper cable) Operating temperature range: +1 degrees C to +85 degrees Construction: Self extinguishing polymer 66 Monofilaments according to ISO 3795 Braid with straight canned copper sensing veins. Color: Gray / blue Approvals: BS EN ISO 9001: 1994, EMC Directive 89/336 / EEC CE

  • Elektriksel Yangınlar  Otomatik Söndürme Sistemleri | Platin Teknoloji

    DLP Micro Automatic Fire Suppression Systems The biggest fire risks in businesses are accepted by all authorities where the electrical infrastructure is located in the central panels. Platinum technology has developed cabinet type extinguishing systems that provide low initial investment and operating costs and high performance for electrical panels and cabinets where risks are concentrated. HFC227ea, FM200 and HFC125 VB extinguishing gases used in the fire extinguishing system provide effective extinguishing. These gases are odorless, colorless, non-residual gases that do not harm electrical material. The system can be set up in 2 different ways. 1: DIRECT SYSTEMS The efficiency of its system comes from the heat sensitive hose it has. With the effect of the heat generated as a result of the flame, it reacts very quickly and tears occur in the hose at a point where it is most intense and the extinguishing gas is discharged into the environment. The system consists of tube, valve and sensitive hose. Micro extinguishing solutions are an automatic system with a flexible red detection hose that ends the fire when it starts. The detection hose is made of polymer mixed materials to work best. FireDeTec protects the fire area not from a numbered place, but from everywhere the detection hose passes. In addition to being able to work alone, this system can also be operated with an alarm system or a manual button or valve. Why is it so effective? Because the detection hose passes through all sides of the place to be protected, it detects and extinguishes the resulting fire from the central place, that is, from where it first emerged. The detection hose is not affected by moisture, dirt and irregular air flow. It does the job of perception under all circumstances. Pressurized sense hose is placed inside the protected area. In case of fire, the hose on the side of the fire source melts and explodes when it feels the small fire. The extinguishing agent is released from the explosion and extinguishes the fire in a smaller flame. The alarm system, which is adapted optionally, is also activated. The system can be installed in a wide variety of sizes and lengths. In the direct direct system, there is a fire extinguisher body with extinguishing agent and a detection hose. The detection hose is pressurized with nitrogen gas up to the extreme point, it bursts from the point where it detects the flame and acts as a nozzle, discharging the extinguishing material contained in the fire extinguisher body to the area where the fire starts. It minimizes the level of damage caused by the fire due to its early detection from a very small flame. Direct system is generally used in all electrical devices and panels, information system rooms, raised floor cables, engine rooms of yachts, UPS rooms, telephone switchboard panels, automobile engines, armored vehicles engine compartments, work machines, etc. It is used in places. 2: INDIRECT SYSTEMS The difference from direct systems is that the extinguishing gas is also discharged into the environment through the established pipes. In the event of a possible fire, a rupture occurs in the hose, this triggers the tube and the gas is discharged into the environment. The system consists of tube, valve, piping and sensitive hose. Scope of application Electric panels System rooms Electrical machines Cabins

  • news from us | Platinum Technology

    NEWS FROM US Platinum Technology Innovations With a quarter of a century of experience, we offer solutions throughout Turkey with the world's leading brands for sectoral risks and security problems specific to projects. VDS has deemed the use of thermal cameras suitable for early fire detection solutions in difficult and risky areas. You can reach our article on thermal camera applications in early fire detection solutions on www.insaatteümrük.com.tr magazine, January - February 2021 issue, Pages 110-111. Green solutions for smart cities We produce environmentally friendly solutions for local governments. Thanks to solar solutions, it is time to switch to smart poles from the classical poles where the lighting is provided in the streets and advertising postings are hung on some central areas. We offer solutions without requiring mains voltage. So what is there in the smart pole; Solar Led Armature LIGHTING for the main task of lighting Wi-Fi INTERNET to provide internet connection around Next generation smart cameras for security. Traffic analysis according to pole position, Social incident, Face recognition, Panic analysis, Perimeter security, Speed violation, Lane violation, Pedestrian protection etc. CAMERA Environmental data analysis with environmental data analysis software with temperature, rain, wind, air quality sensors. ENVIRONMENT Intelligent direct emergency security point SECURITY to quickly access security forces in case of possible emergency with panic button Voice and video conversation with security forces in case of emergency with intercom. COMMUNICATION In addition to generating revenue for municipalities, the body of the pole and the advertising areas on it will also provide public announcements to be shared effectively and instantly. ADVERTISEMENT With the environmentally friendly energy obtained from the solar panel, the charging station of the disabled vehicles, electric bicycles, scoters, etc. ENVIRONMENTAL ENERGY Charging station for mobile devices such as phones, tablets, etc. EMERGENCY It creates high comfort areas on streets, streets, parks, gardens and beaches with new generation smart, environmentally friendly and safe municipal applications. Fire Detection Solutions with Linear Heat Detectors Although the smoke and heat emerging at the first occurrence of the fire are detected most effectively with the point type fire detection detectors, there are operational risks such as faulty alarm, late detection, rapid contamination, dust collection in the detector cell due to the conditions of industrial areas. You can access our article on linear heat detection in Industrial Facilities from www.insaatteümrük.com.tr magazine, September, October 2020 issue. Integration of Fire Detection and Alarm Systems with Other Systems Operation, control, integrated operation of various other systems established for fire detection, extinguishing and evacuation in buildings and preventing risks by controlling from a single point; It is necessary for the systems to work properly and in harmony with their duties at the time of detection of a possible fire. The management and control platform where all these systems will be integrated are fire detection or central automation systems. Thanks to this integration, effective fire response, rapid evacuation and keeping the systems under control from a single center provide fast and effective intervention to possible failures.

  • Yaslı ve Engellilere Yönelik  Evde Panik Buton Sistemi Platin Teknoloji

    Elderly Support, Home Care Automation System Home Care; Effective care and safety automation for Elderly, Sick and Handicapped individuals living alone or in need of care at home. Automation solutions for public institutions and municipalities that provide disabled and elderly support services: Elderly and disabled individuals living alone in their homes; Monitoring health conditions in digital environment Informing the relevant health authority when necessary Ensuring the safety of elderly people Meeting the personal needs of elderly people Supporting elderly people to live in their homes We offer electronic solutions to increase the quality of life and ensure their social integration. What is Followed in Home Care Service. Health Risks Pulse Temperature Fall Don't leave the house Asking for help with a panic button Security Risks Fire, smoke, Gas detection Anti-theft alarm Water and flood alarm Social help Follow-up of social service needs such as cleaning, food, etc. How does it work Disabled, Sick, Elderly person communicates with the center by pressing the button whenever deemed necessary with the portable wristband or necklace type and the panic button. The conversation starts with the call center operator as soon as the button is pressed, and bidirectional communication is provided in this way. It can be provided in conversation with the hands-free microphone and speaker on the panel. Panic button also measures body temperature, (Optional Pulse, oximeter and fall sensor) alarm scenarios continue to function just like when the panic button is pressed, in case of exceeding the specified level; At the same time, this information reaches the call center in parallel, and the process is followed, confirmed and reported simultaneously; Application user can be backed up in parallel. The system is open to developments. It can add suitable new generation medical devices. TECHNICAL SPECIFICATIONS 7/24 Professional monitoring and control Two-way voice conversation via GSM connected panel Panel touch and voice guided Functional emergency buttons on it Panel communicates centrally with TCP / IP over 3G or GPRS 869 MHZ wireless communication with panel equipment Parallel alarm center connection Meeting with the center in case of emergency by means of a button Informing the center automatically in case of violation, detection and alarm Periodic communication test signal Waterproof and long battery life pan button Measuring body temperature via panic button Alarm sending over 38 ' Tracking via mobile application Drug programming via mobile application Tamper, low battery, communication error notification Backup battery against power outages Suitable for wall mounting or desktop use Warning against dismantling and sabotage EN 50131 Grade 2 compliant Wireless security equipment support OPTIONAL FEATURES Drop sensor Heart rate sensor Oxidation sensor It is the system features known as the emergency call panic button for the elderly in the society. FOR OUR OTHER ELECTRONIC ACCESSIBILITY SOLUTIONS

bottom of page